AI Paper Atlas

Research map / Reinforcement learning / Visual and representation RL

MTDiag: An Effective Multi-Task Framework for Automatic Diagnosis

Zhenyu Hou, Yukuo Cen, Ziding Liu, Dongxue Wu, Baoyan Wang, Xuanhe Li, Lei Hong, Jie Tang

AAAI 2023 · Reinforcement learning › Visual and representation RL · approach: Inferring decision-making from behavior · 5 citations (OpenAlex)

This paper tried a common change: Add a contrastive loss

Add supervised contrastive learning · MDD dev · accuracy: 88.1 -> 89.1 Improved

What 1,317 accepted papers report for this change

See this change in detailMatched by the wording of each paper's own result, read by AI from the full text. Papers report gains more often than failures, so this shows what gets published, not the chance a change works.

Read the paper

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use MTDiag instead of Diaformerautomatic diagnosis · MDD devaccuracy: 86.0 -> 89.1Improved
Use MTDiag instead of Diaformerautomatic diagnosis · MZaccuracy: 74.2 -> 75.9Improved
Use MTDiag instead of Diaformerautomatic diagnosis · DXYaccuracy: 82.9 -> 85.4Improved
Use MTDiag instead of Diaformerautomatic diagnosis · Syntheticaccuracy: 73.3 -> 75.4Improved
Add supervised contrastive learning (ablation)MTDiag · MDD devaccuracy: 88.1 -> 89.1Improved
Add supervised contrastive learning (ablation)MTDiag · MZaccuracy: 74.2 -> 75.9Improved
Add supervised contrastive learning (ablation)MTDiag · DXYaccuracy: 84.0 -> 85.4Improved
Add supervised contrastive learning (ablation)MTDiag · Syntheticaccuracy: 75.6 -> 75.4No clear effect
Use concurrent softmax rather than BCE while retaining multi-task disease information (ablation)MTDiag · MDD devaccuracy: 88.7 -> 89.1Improved
Use concurrent softmax rather than BCE while retaining multi-task disease information (ablation)MTDiag · MZaccuracy: 74.2 -> 75.9Improved
Use concurrent softmax rather than BCE while retaining multi-task disease information (ablation)MTDiag · DXYaccuracy: 84.8 -> 85.4Improved
Use concurrent softmax rather than BCE while retaining multi-task disease information (ablation)MTDiag · Syntheticaccuracy: 74.1 -> 75.4Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy