AI Paper Atlas

Research map / Large language models / Language, safety and interpretability

Calibrate Before Use: Improving Few-shot Performance of Language Models

ICML 2021 · Large language models › Language, safety and interpretability · approach: In-context learning analysis · 72 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's title only (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Apply contextual calibration to GPT-3 2.7BGPT-3 2.7B few-shot prompting · SST-2, 4-shotaccuracy: 59.1_{ 10.2} -> 79.9_{ 7.8}Helped
Apply contextual calibration to GPT-3 2.7BGPT-3 2.7B few-shot prompting · DBPedia, 1-shotaccuracy: 25.9_{ 4.4} -> 61.6_{ 2.9}Helped
Apply contextual calibration to GPT-3 2.7BGPT-3 2.7B few-shot prompting · AGNews, 4-shotaccuracy: 43.3_{ 8.3} -> 71.1_{ 8.5}Helped
Apply contextual calibration to GPT-3 2.7BGPT-3 2.7B few-shot prompting · LAMA, 4-shotaccuracy: 35.8_{ 3.8} -> 37.4_{ 3.4}Helped
Apply contextual calibration to GPT-3 175BGPT-3 175B few-shot prompting · RTE, 1-shotaccuracy: 62.9_{ 2.7} -> 62.8_{ 2.3}No clear effect
Apply contextual calibration to GPT-3 175BGPT-3 175B few-shot prompting · SST-2, 8-shotaccuracy: 95.6_{ 1.0} -> 95.3_{ 0.7}No clear effect
Apply contextual calibration to GPT-2GPT-2 few-shot prompting · CB, 0-shotaccuracy: 44.6_{ \text{0.0}} -> 17.9_{ \text{0.0}}Hurt
Apply contextual calibration to GPT-2GPT-2 few-shot prompting · DBPedia, 0-shotaccuracy: 64.3_{ \text{0.0}} -> 58.3_{ \text{0.0}}Hurt
Use N/A alone instead of the three-input ensemble (ablation)Contextual calibration on SST-2 · SST-2, 1-shotaccuracy: 79.0 -> 74.2Hurt
Use [MASK] alone instead of the three-input ensemble (ablation)Contextual calibration on SST-2 · SST-2, 1-shotaccuracy: 79.0 -> 74.5Hurt
Use the empty string alone instead of the three-input ensemble (ablation)Contextual calibration on SST-2 · SST-2, 1-shotaccuracy: 79.0 -> 72.9Hurt
Use the man. instead of the three-input ensemble (ablation)Contextual calibration on SST-2 · SST-2, 1-shotaccuracy: 79.0 -> 79.4No clear effect