Measured effects reported in the paper

What was changedWhereMeasuredEffect
Replace reservoir sampling / GSS memory population with class-balancing reservoir sampling (CBRS)online continual learning memory population · MNIST, Fashion-MNIST, CIFAR-10, CIFAR-100 (imbalanced streams)test accuracy: MNIST 83.3 vs 74.2 (GSS); CIFAR-100 40.2 vs 28.1 (reservoir)Improved
Use uniform instead of weighted replay with CBRS (ablation)CBRS · MNIST m=1000 and CIFAR-10 m=1000test accuracy: MNIST 86.0 vs 86.1; CIFAR-10 74.4 vs 73.7 (m=1000)No clear effect
Use weighted instead of uniform replay with reservoir sampling (ablation)RESERVOIR · MNIST m=1000 and CIFAR-10 m=1000test accuracy: MNIST 76.3 vs 71.3; CIFAR-10 56.7 vs 54.2Improved
Use weighted instead of uniform replay with CBRS at m=5000 (ablation)CBRS · MNIST and CIFAR-10 m=5000test accuracy: MNIST 90.3 vs 85.6; CIFAR-10 78.3 vs 76.8Mixed
Increase memory size from 100 to 5000 with CBRSCBRS · Fashion-MNISTtest accuracy: 66.5 at m=100 to 77.1 at m=5000Improved
Add CBRS memory overhead (index structure per class) vs GSS gradient storagememory population · CIFAR-100 computewall-clock time per batch and memory overhead: CBRS 0.03% overhead vs GSS 3639.86%; CBRS 3671.1 ms vs GSS 364.9 ms (time per batch)Improved
Replace reservoir sampling with GSS-Greedy memory populationonline continual learning memory population · CIFAR-100 (ResNet-18, m=1000)test accuracy: 23.0 vs 28.1 for reservoirHurt
Use weighted replay (inverse-class-count sampling) instead of uniform replay for all methods (ablation)online CL replay · MNIST, CIFAR-10 at m=1000 and m=5000test accuracy: Gains for RESERVOIR/GSS; none for CBRS at m=1000 (86.0 vs 86.1)Mixed