atlas

Research map / Architectures and efficiency / RNNs and normalization

Jumpout : Improved Dropout for Deep Neural Networks with ReLUs

ICML 2019 · Architectures and efficiency › RNNs and normalization · approach: Normalization layer theory · 12 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's title only (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
replace constant dropout with jumpout (monotone sampled rate, adaptive normalization, rescaling)DNNs with ReLU across CIFAR10(s), CIFAR10, CIFAR100, Fashion-MNIST, STL10, SVHN, ImageNet · test accuracy, 10 trialstest accuracy (%): e.g. +3.75 on CIFAR10(s), +1.48 on CIFAR10, +2.88 on CIFAR100, +1.28 on Fashion, +2.78 on STL10, +0.21 on SVHN, +0.34 onHelped
add monotone (half-Gaussian) sampled dropout rate (modification I) (ablation)dropout on small CNN and WideResNet · CIFAR10(s), CIFAR10, CIFAR100, STL10test accuracy (%): +1.06 CIFAR10(s), +0.85 CIFAR10, +0.48 CIFAR100, +0.39 STL10Helped
add adaptive dropout rate normalization by fraction of active neurons (modification II) (ablation)dropout on small CNN and WideResNet · CIFAR10(s), CIFAR10, CIFAR100, STL10test accuracy (%): +0.71 CIFAR10(s), +0.46 CIFAR10, +0.90 CIFAR100, +0.57 STL10Helped
add rescaling with (1-p)^-0.75 to work with BN (modification III) (ablation)dropout on small CNN and WideResNet · CIFAR10(s), CIFAR10, CIFAR100, STL10test accuracy (%): +1.27 CIFAR10(s), +0.97 CIFAR10, +1.20 CIFAR100, +0.32 STL10Helped
combine modifications I and II vs. dropout (ablation)dropout · CIFAR10(s)test accuracy (%): +3.56 over dropout 86.50Helped
add modification III (rescaling) on top of II (ablation)dropout+II · CIFAR10(s)test accuracy (%): 89.64 vs 87.14 without IIIHelped
add modification I on top of III (ablation)dropout+III · CIFAR10(s)test accuracy (%): 87.36 vs 87.70 without INo clear effect
all three modifications together vs. any pair (ablation)dropout · CIFAR100 (WideResNet-28-10)test accuracy (%): 82.48 vs 81.70 for best pair (I+II)Helped