atlas

Research map / Label-efficient and robust learning / Zero-/few-shot and meta-learning

BECLR: Batch Enhanced Contrastive Few-Shot Learning

ICLR 2024 · Label-efficient and robust learning › Zero-/few-shot and meta-learning · approach: Alignment-based few-shot metric learning · 2 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes BECLR, a contrastive unsupervised few-shot learning method with a dynamic clustered memory (DyCE) for enhanced positive sampling and an optimal-transport distribution alignment (OpTA) at inference to reduce support-query sample bias.

Problem

Unsupervised few-shot learning suffers from instance-level contrastive positives being wrongly repelled within batches and from sample bias between few labeled support prototypes and the unlabeled query distribution at inference.

Approach

A dynamically updated clustered memory with optimal-transport-based equipartitioned prototypes supplies extra nearest-neighbor positives for contrastive pretraining (DyCE), and an iterative optimal-transport alignment moves support prototypes toward query embeddings at inference without learnable parameters (OpTA).

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add DyCE (ablation)BECLR with masking and EMA teacher · miniImageNet 5-way 1-shotaccuracy (%): 65.33 -> 67.75Helped
add DyCE (ablation)BECLR with masking and EMA teacher · miniImageNet 5-way 5-shotaccuracy (%): 82.69 -> 85.53Helped
add OpTA (ablation)BECLR with masking, EMA teacher, and DyCE · miniImageNet 5-way 1-shotaccuracy (%): 67.75 -> 80.57Helped
add OpTA (ablation)BECLR with masking, EMA teacher, and DyCE · miniImageNet 5-way 5-shotaccuracy (%): 85.53 -> 87.82Helped
use masking without EMA teacher, DyCE, or OpTA (ablation)BECLR · miniImageNet 5-way 1-shotaccuracy (%): 63.57 -> 54.53Hurt
add masking and EMA teacher together (ablation)BECLR without components · miniImageNet 5-way 1-shotaccuracy (%): 63.57 -> 65.33Helped
replace DyCE partitioned memory with FIFO memory (ablation)BECLR · miniImageNet 5-way 5-shotaccuracy (%): 87.82 -> 84.05Hurt
replace optimal transport updates with kMeans (ablation)BECLR · miniImageNet 5-way 5-shotaccuracy (%): 87.82 -> 85.37Hurt
set masking ratio to 50% or 70% instead of 30% (ablation)BECLR · miniImageNet 5-way 5-shotaccuracy (%): 87.82 -> 83.36; 87.82 -> 77.70Hurt
set output dimension to 256 or 1024 instead of 512 (ablation)BECLR · miniImageNet 5-way 5-shotaccuracy (%): 87.82 -> 85.16; 87.82 -> 85.93Hurt
increase the negative loss weight from 0.1 to 0.3 (ablation)BECLR · miniImageNet 5-way 5-shotaccuracy (%): 87.82 -> 86.33Hurt
increase nearest neighbors beyond k=3 (ablation)BECLR · miniImageNet 5-way 5-shotaccuracy (%)Hurt

Surprising findings

Limitations

Experimental setup

Datasets: miniImageNet tieredImageNet CIFAR-FS FC100 CUB ChestX ISIC EuroSAT CropDiseases

Benchmarks: miniImageNet tieredImageNet CIFAR-FS FC100 CUB ChestX ISIC EuroSAT CropDiseases

Metrics: accuracy (%) with 95% confidence intervals over 2000 episode

Baselines: SwAV NNCLR SimSiam PsCo UniSiam + dist Meta-DM + UniSiam + dist SAMPTransfer HMS PDA-Net ConFeSS SimCLR MoCo v2

Builds on: NNCLR UniSiam PsCo Sinkhorn-Knopp

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy