(Certified!!) Adversarial Robustness for Free!

ICLR 2023 · Adversarial robustness and security › Certified and empirical robustness · approach: Certified training and ensembles · 17 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's title only (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
combine a pretrained diffusion denoiser with an off-the-shelf classifier for randomized smoothingImageNet classification · ImageNetcertified top-1 accuracy at ε=0.5 (%): 57.0 -> 71.1Helped
use diffusion denoised smoothing rather than the strongest listed baselineImageNet classification · ImageNet, ε=3.0certified top-1 accuracy (%): 23.4 -> 13.1Hurt
use diffusion denoised smoothing with an off-the-shelf ViTCIFAR-10 classification · CIFAR-10, ε=0.25certified accuracy (%): 74.9 -> 76.7Helped
replace ViT with CIFAR-10-only Wide-ResNet (ablation)Diffusion Denoised Smoothing · CIFAR-10, ε=0.5certified accuracy (%): 63.0 -> 55.7Hurt
finetune Wide-ResNet on noised-then-denoised training images (ablation)Diffusion Denoised Smoothing · CIFAR-10, ε=0.5certified accuracy (%): 55.7 -> 63.8Helped
finetune ViT on noised-then-denoised training images (ablation)Diffusion Denoised Smoothing · CIFAR-10, ε=0.5certified accuracy (%): 63.0 -> 65.5Helped
train the diffusion denoiser on three noise levels instead of only σ=0.5 (ablation)one-shot denoising with ViT · CIFAR-10 denoised images, evaluation σ=0.5clean accuracy: 60.1 -> 68.1Helped
train the denoiser on a broad standard noise range instead of only σ=0.5 (ablation)one-shot denoising with ViT · CIFAR-10 denoised images, evaluation σ=0.5clean accuracy: 60.1 -> 72.3Helped
train the denoiser on the standard broad range rather than [0, 1.0] (ablation)one-shot denoising with ViT · CIFAR-10 denoised images, evaluation σ=1.0clean accuracy: 46.0 -> 44.8Hurt
use deterministic multi-step EDM sampling instead of one-shot denoising (ablation)diffusion denoising with ViT · CIFAR-10 denoised images, σ=1.0clean accuracy: 50.8 -> 54.0Helped