atlas

Research map / Label-efficient and robust learning / Noisy labels

Sample Selection with Uncertainty of Losses for Learning with Noisy Labels

ICLR 2022 · Label-efficient and robust learning › Noisy labels · approach: Noise-aware loss and pairwise methods · 47 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's title only (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use CNLCU-S with uncertainty-aware sample selectionnoisy-label learning · Clothing1M Besttest accuracy (%): +1.28% over the best baseline JoCorHelped
Use CNLCU-S with uncertainty-aware sample selectionnoisy-label learning · Clothing1M Lasttest accuracy (%): +1.01% over JoCorHelped
Use uncertainty-aware CNLCU selectionnoisy-label learning · synthetic balanced datasets with multiple noise typestest accuracyHelped
Add conservative selection of less-selected, large-loss examples (ablation)CNLCU-S · MNIST and F-MNIST noisy-label settingstest accuracy (%): 98.02 -> 98.82 (MNIST Sym. 20%); 72.93 -> 83.14 (F-MNIST Asym. 40%)Helped
Add robust multi-iteration estimation for small-loss examples (ablation)CNLCU-S · MNIST and F-MNIST noisy-label settingstest accuracy (%): 98.15 -> 98.82 (MNIST Sym. 20%); 80.99 -> 83.14 (F-MNIST Asym. 40%)Helped
Replace non-robust mean with robust mean estimation (ablation)Co-teaching-M · MNIST noisy-label settingstest accuracy (%): 97.72 -> 98.82 (Sym. 20%)Helped
Add conservative selection of less-selected, large-loss examples (ablation)CNLCU-H · MNIST and F-MNIST noisy-label settingstest accuracy (%): 98.06 -> 98.70 (MNIST Sym. 20%); 71.35 -> 82.69 (F-MNIST Asym. 40%)Helped
Add robust multi-iteration estimation for small-loss examples (ablation)CNLCU-H · MNIST and F-MNIST noisy-label settingstest accuracy (%): 98.19 -> 98.70 (MNIST Sym. 20%); 80.73 -> 82.69 (F-MNIST Asym. 40%)Helped
Vary the fixed-length loss time interval within the tested ranges (ablation)CNLCU-S and CNLCU-H · MNIST and F-MNIST noisy-label settingstest accuracyNo clear effect
Use CNLCU to encourage selection of underrepresented examplesnoisy-label learning · IM-MNIST and IM-F-MNISTtest accuracy: nearly 30% lead in IM-MNIST Asym. 10%; about 5% lead on IM-F-MNISTHelped
Use conservative uncertainty-based selectionCNLCU · IM-MNIST and IM-F-MNISTselected ratio (%): 0.60 vs 0.10 (IM-MNIST 10% noise, CNLCU-S vs MentorNet)Helped

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy