atlas

Research map / Image generation / Autoregressive and latent generation

Toward Generalized Image Quality Assessment: Relaxing the Perfect Reference Quality Assumption

CVPR 2025 · Image generation › Autoregressive and latent generation · approach: Learning-based image quality assessment · 15 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Builds DiffIQA (~180k diffusion-enhanced test images with human worse/similar/better labels vs. reference) and SRIQA-Bench, and proposes A-FINE, a full-reference IQA model that adaptively combines a DISTS-like fidelity term and a naturalness term so it works when the reference is imperfect.

Problem

Full-reference IQA models assume the reference image has perfect quality, which fails when references are degraded or when enhancement methods produce outputs better than the reference.

Approach

Model quality as an adaptive linear combination of a fidelity term (DISTS-like, on CLIP ViT features) and a naturalness term of the test image, with the weight driven by the difference in naturalness between reference and test; it reduces to standard FR-IQA when the reference is much more natural than the test image.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use A-FINE instead of TOPIQFR-IQA evaluation on TID2013 · TID2013 testaccuracy (%): 90.4 -> 88.1Hurt
use A-FINE instead of TOPIQFR-IQA evaluation on KADID-10K · KADID-10K testaccuracy (%): 94.3 -> 88.3Hurt
use A-FINE instead of TOPIQFR-IQA evaluation on PIPAL · PIPAL testaccuracy (%): 80.5 -> 81.0Helped
use A-FINE instead of TOPIQ-FTFR-IQA evaluation on DiffIQA · DiffIQA averageaccuracy (%): 77.0 -> 79.9Helped
use A-FINE instead of TOPIQ-FTFR-IQA evaluation on SRIQA-Bench · SRIQA-Bench generation-basedaccuracy (%): 73.0 -> 78.9Helped
replace CLIP ViT-B/32 with VGG16 (ablation)A-FINE · Standard IQA averageaccuracy (%): 83.6 -> 77.6Hurt
replace CLIP ViT-B/32 with ImageNet-trained ResNet50 (ablation)A-FINE · Standard IQA averageaccuracy (%): 83.6 -> 74.8Hurt
replace CLIP ViT-B/32 with CLIP-trained ResNet50 (ablation)A-FINE · Standard IQA averageaccuracy (%): 83.6 -> 76.1Hurt
replace CLIP ViT-B/32 with ImageNet-trained ViT-B/32 (ablation)A-FINE · Standard IQA averageaccuracy (%): 83.6 -> 81.0Hurt
train on standard IQA datasets only, without DiffIQA (ablation)A-FINE · DiffIQA averageaccuracy (%): 79.9 -> 65.6Hurt
train on DiffIQA only, without standard IQA datasets (ablation)A-FINE · Standard IQA averageaccuracy (%): 83.6 -> 70.6Hurt
replace combined training data with standard IQA datasets only (ablation)A-FINE · SRIQA-Bench allaccuracy (%): 82.4 -> 78.7Hurt

Surprising findings

Limitations

Experimental setup

Datasets: TID2013 KADID-10K PIPAL DiffIQA DF2K DIV8K FFHQ LSDIR SRIQA-Bench

Benchmarks: TID2013 KADID-10K PIPAL DiffIQA SRIQA-Bench

Metrics: accuracy (%)

Baselines: PSNR SSIM MS-SSIM FSIM VSI LPIPS DISTS AHIQ TOPIQ VIF PCQI SFSN

Builds on: DISTS PASD UNIQUE CKDN Thurstone's Case V model

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy