atlas

Research map / Label-efficient and robust learning / Semi-supervised learning

STiL: Semi-supervised Tabular-Image Learning for Comprehensive Task-Relevant Information Exploration in Multimodal Classification

CVPR 2025 · Label-efficient and robust learning › Semi-supervised learning · approach: Confidence-based pseudo-label selection · 5 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes STiL, a semi-supervised image-tabular learning framework that combines disentangled contrastive consistency, consensus-guided pseudo-labeling, and prototype-guided label smoothing to recover task-relevant modality-specific and shared information from few labels.

Problem

Multimodal image-tabular classification with limited labeled data; existing SSL and multimodal SemiSL methods focus on shared or unimodal features and miss task-relevant modality-specific information (the "Modality Information Gap").

Approach

Jointly disentangles modality-shared and modality-specific features with contrastive consistency and CLUB-based mutual-information minimization, generates pseudo-labels via rule-based consensus among a multimodal and two unimodal classifiers, and smooths pseudo-labels with prototype similarity stored as class-level embeddings.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use STiL instead of TIPmultimodal image-tabular classification · DVM, 1% labeled dataaccuracy (%): 88.93 -> 91.92Helped
use STiL instead of SAINTmultimodal image-tabular classification · CAD, 1% labeled dataAUC (%): 78.02 -> 83.54Helped
use STiL instead of SAINTmultimodal image-tabular classification · Infarction, 1% labeled dataAUC (%): 75.63 -> 82.64Helped
use STiL instead of Self-KDmultimodal image-tabular classification · DVM, 1% labeled dataaccuracy (%): 90.45 -> 91.92Helped
use STiL instead of Co-trainingmultimodal image-tabular classification · CAD, 1% labeled dataAUC (%): 81.00 -> 83.54Helped
add DCC, CGPL, and PGLS to the labeled-only baseline (ablation)STiL · DVM, CAD, and Infarction, 1% labeled dataaccuracy (%) / AUC (%): 82.98 -> 91.92; 75.75 -> 83.54; 73.70 -> 82.64Helped
add DCC to the baseline (ablation)STiL · DVM, CAD, and Infarction, 1% labeled dataaccuracy (%) / AUC (%): 82.98 -> 89.43; 75.75 -> 81.26; 73.70 -> 74.04Mixed
add CGPL to the baseline (ablation)STiL · DVM, CAD, and Infarction, 1% labeled dataaccuracy (%) / AUC (%): 82.98 -> 83.82; 75.75 -> 83.59; 73.70 -> 78.39Helped
add contrastive consistency without disentanglement losses (ablation)STiL baseline · CAD and Infarction, 1% labeled dataAUC (%): 75.75 -> 80.95; 73.70 -> 71.70Mixed
add disentanglement losses to contrastive consistency (ablation)STiL baseline · CAD and Infarction, 1% labeled dataAUC (%): 80.95 -> 83.59; 71.70 -> 78.39Helped
remove intra- and inter-modality interaction (ablation)STiL · DVM, CAD, and Infarction, 1% labeled dataaccuracy (%) / AUC (%): 90.83 vs 91.92; 81.25 vs 83.54; 81.03 vs 82.64Hurt
remove consensus collaboration from pseudo-labeling (ablation)STiL · DVM, CAD, and Infarction, 1% labeled dataaccuracy (%) / AUC (%): 89.88 vs 91.92; 82.23 vs 83.54; 75.08 vs 82.64Hurt

Surprising findings

Limitations

Experimental setup

Datasets: DVM UK Biobank

Benchmarks: DVM UK Biobank CAD UK Biobank Infarction

Metrics: accuracy AUC

Baselines: ResNet-50 DAFT Interact Fuse TIP SimCLR BYOL SCARF SAINT MMCL CoMatch SimMatch FreeMatch

Builds on: FixMatch-style weak-strong consistency TIP MMCL CLUB SimMatch

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy