AI Paper Atlas

Research map / Detection and segmentation / Open-set and few-shot detection

Retinomorphic Object Detection in Asynchronous Visual Streams

Jianing Li, Xiao Wang, Lin Zhu, Jia Li, Tiejun Huang, Yonghong Tian

AAAI 2022 · Detection and segmentation › Open-set and few-shot detection · approach: Unsupervised object and part discovery · 27 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Fuse Vidar spikes and DVS events using TAR and dynamic interactionYOLOv3 retinomorphic detector · PKU-Vidar-DVSmAP: 0.591 -> 0.647Improved
Fuse Vidar spikes and DVS events using TAR and dynamic interactionYOLOv3 retinomorphic detector · KITTI simulatedmAP: 0.718 -> 0.762Improved
Use TAR-spikes instead of VTII (ablation)Vidar YOLOv3 baseline · PKU-Vidar-DVSmAP: 0.551 -> 0.579Improved
Add TAR-events to the TAR-spikes variant (ablation)YOLOv3 retinomorphic detector · PKU-Vidar-DVSmAP: 0.579 -> 0.606Improved
Add dynamic interaction fusion (ablation)TAR-based YOLOv3 detector · PKU-Vidar-DVSmAP: 0.606 -> 0.623Improved
Add ℓ1 regulation for channel sparsity (ablation)TAR-based YOLOv3 detector with dynamic interaction · PKU-Vidar-DVSmAP: 0.623 -> 0.647Improved
Replace dynamic interaction with typical fusion methods (ablation)TAR-based YOLOv3 detector · PKU-Vidar-DVSmAP: 0.647 versus 0.612; 0.647 versus 0.615; 0.647 versus 0.619; 0.647 versus 0.623; 0.647 versus 0.621; 0.647 versus 0.624; Hurt
Increase temporal aggregation size from T=1 to T=3 (ablation)Retinomorphic detector · PKU-Vidar-DVSmAP: 0.623 -> 0.647Improved
Increase temporal aggregation size from T=3 to T=5 (ablation)Retinomorphic detector · PKU-Vidar-DVSmAP: 0.647 -> 0.649Improved
Increase temporal aggregation size from T=5 to T=7 or T=9 (ablation)Retinomorphic detector · PKU-Vidar-DVSmAP: 0.649; 0.650; 0.650No clear effect
Increase temporal aggregation size from T=3 to T=7 (ablation)Retinomorphic detector · KITTI simulatedmAP: 0.762 -> 0.769Improved
Increase temporal aggregation size from T=7 to T=9 (ablation)Retinomorphic detector · KITTI simulatedmAP: 0.769 -> 0.768Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy