Research map / Large language models / Language, safety and interpretability
FactCheXcker: Mitigating Measurement Hallucinations in Chest X-ray Report Generation Models
Read the paperCheck your idea against 108,967 papers
AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Proposes FactCheXcker, a modular query-code-update pipeline that uses GPT-4o mini to generate measurement queries and code over a tool API to correct endotracheal tube measurements in chest X-ray reports from 11 report generation models.
Problem
Medical vision-language report generation models hallucinate quantitative measurements (e.g., endotracheal tube-to-carina distance), which undermines clinical reliability.
Approach
A training-free, tool-based post-hoc pipeline: an LLM generates measurement queries from the report, writes Python code calling specialized vision tools (exists, find, distance, etc.), and a report updater injects verified measurements and placement judgments back into the report, without retraining the original model.
Key results
- Across 11 report generation models, FactCheXcker improves ETT measurement MAE by an average of 135.0% (average MAE 7.25 to 2.54 and composite improvement of 186%).
- ETT presence precision rises on average from 0.49 to 0.65, with LLM-CXR improving most (0.08 to 0.58).
- Average ETT placement precision increases from 0.84 to 0.94; GPT4V failure rate drops from 77.5% to 22.5%.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Apply FactCheXcker to report-generation models | 11 chest X-ray report-generation models · MIMIC-CXR test, ETT measurement | MAE: 1.93 -> 0.82; 135.0% | Helped |
| Apply FactCheXcker to report-generation models | 11 chest X-ray report-generation models · MIMIC-CXR test, ETT placement | Precision: 0.84 -> 0.94 | Helped |
| Apply FactCheXcker to RadFM reports | RadFM · MIMIC-CXR test, ETT measurement | MAE: 0.65 -> 1.04; -38.0% | Hurt |
| Apply FactCheXcker to RadFM reports | RadFM · MIMIC-CXR test, ETT measurement | Composite: 8.12 -> 11.56; -30.0% | Hurt |
| Apply FactCheXcker to GPT4V reports | GPT4V · MIMIC-CXR test, ETT measurement | MAE: 2.35 -> 0.39; 503.0% | Helped |
| Apply FactCheXcker to LLM-CXR reports | LLM-CXR · MIMIC-CXR test, ETT measurement | MAE: 2.41 -> 0.91; 165.0% | Helped |
| Apply FactCheXcker to VLCI reports | VLCI · MIMIC-CXR test, ETT measurement | MAE: 3.50 -> 0.98; 257.0% | Helped |
Surprising findings
- RadFM's measurement MAE worsened after applying FactCheXcker (-30%), showing the pipeline can occasionally make measurements worse.
- Running FactCheXcker on every image regardless of report mentions improves false negatives but significantly drops precision.
Limitations
- Evaluated only on endotracheal tube placement; other measurement types (lesions, nodules) not addressed.
- Placement uses a strict rule-based threshold (3-7 cm) because GPT-4o mini numeric reasoning is insufficient.
- Failure cases from tube misidentification and obscured carina landmarks; false positive rate depends on exists module.
Experimental setup
Datasets: MIMIC-CXR 2.0.0 CheXpert Plus private dataset (22 hospitals)
Benchmarks: MIMIC-CXR test set (2288 studies, 182 with ETT mentions)
Metrics: precision MAE composite (MAE x F1) F1 balanced accuracy failure rate (error > 1.5 cm) placement precision
Baselines: CheXagent CheXpertPlus GPT-4V LLM-CXR MAIRA-2 MedVersa RadFM RaDialog RGRG VLCI Cvt2distilgpt2
Builds on: ViperGPT HuggingGPT CarinaNet ResNet-50
Closest papers by meaning
- Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation (NeurIPS 2026 · similarity 0.84)
- CXReasonBench: A Benchmark for Evaluating Structured Diagnostic Reasoning in Chest X-rays (NeurIPS 2025 · similarity 0.84)
- LLM-RG4: Flexible and Factual Radiology Report Generation Across Diverse Input Contexts (AAAI 2025 · similarity 0.82)
- ReFINE: A Reward-Based Framework for Interpretable and Nuanced Evaluation of Radiology Report Generation (AAAI 2026 · similarity 0.82)
- CXPMRG-Bench: Pre-training and Benchmarking for X-ray Medical Report Generation on CheXpert Plus Dataset (CVPR 2025 · similarity 0.82)
- DAMPER: A Dual-Stage Medical Report Generation Framework with Coarse-Grained MeSH Alignment and Fine-Grained Hypergraph Matching (AAAI 2025 · similarity 0.82)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.