Introduces DiN, a conditional diffusion-based answer classifier for medical VQA trained with semantic noisy labels, plus a noisy-label benchmark built on VQA-RAD and PathVQA.
Problem
Medical VQA models assume clean labels, yet real Med-VQA annotations contain semantically structured label noise from human mislabeling, which existing noise-handling methods (designed for classification or natural VQA) handle poorly.
Approach
Recasts answer classification as a coarse-to-fine conditional diffusion process over answer distributions, conditioned on answer-aware features from a transformer-decoder Answer Condition Generator, and supervised by refined pseudo-labels from a robust focal-symmetric loss and dynamic answer adjustment (Noisy Label Refinement, used only in training).
Key results
- On VQA-RAD with 10% semantic noise, DiN reaches 74.24% overall accuracy versus 69.65% for the best baseline SNLC.
- On VQA-RAD with 20% semantic noise, DiN reaches 62.28% overall accuracy versus 58.88% for SNLC.
- On PathVQA with 20% semantic noise, DiN reaches 58.14% overall accuracy versus 56.72% for SNLC.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Use DiN instead of SNLC | Med-VQA · VQA-RAD 10%-Semantic Noise | overall accuracy: 69.65 -> 74.24 | Helped |
| Use DiN instead of SNLC | Med-VQA · VQA-RAD 20%-Semantic Noise | overall accuracy: 58.88 -> 62.28 | Helped |
| Use DiN instead of SNLC | Med-VQA · VQA-RAD 20%-Random Noise | overall accuracy: 62.03 -> 63.93 | Helped |
| Use DiN instead of SNLC | Med-VQA · PathVQA 10%-Semantic Noise | overall accuracy: 64.18 -> 66.67 | Helped |
| Use DiN instead of SNLC | Med-VQA · PathVQA 20%-Semantic Noise | overall accuracy: 56.72 -> 58.14 | Helped |
| Use DiN instead of SNLC | Med-VQA · PathVQA 20%-Random Noise | overall accuracy: 59.71 -> 60.84 | Helped |
| Add the Answer Diffuser (AD) (ablation) | DiN · VQA-RAD 10%-Semantic Noise | overall accuracy: 68.25 -> 71.15 | Helped |
| Add robust focal loss (RFL) (ablation) | DiN with AD · VQA-RAD 10%-Semantic Noise | overall accuracy: 71.15 -> 72.75 | Helped |
| Add answer adjustment (AA) (ablation) | DiN with AD · VQA-RAD 10%-Semantic Noise | overall accuracy: 71.15 -> 72.25 | Helped |
| Use RFL instead of CE, focal, or SCE loss (ablation) | DiN · VQA-RAD 10%-Semantic Noise | overall accuracy: 72.25; 73.10; 73.50 -> 74.24 | Helped |
| Replace MSE with KL loss for Ldif (ablation) | DiN · VQA-RAD 10%-Semantic Noise | overall accuracy: 74.24 -> 74.00 | No clear effect |
| Vary loss weight α from 0.5 to 0.1 or 1 (ablation) | DiN · VQA-RAD 10%-Semantic Noise | overall accuracy: 74.24; 73.75; 74.18 | No clear effect |
Surprising findings
- Diffusion steps T=50 performed best, far fewer than the 1000 typical in image generation, which the authors attribute to class-distribution rather than pixel-level generation.
- Under 20% noise, the cited SNLC method reached 62% on random noise but dropped to 58% on semantic noise, indicating semantic noise is harder.
Limitations
- Diffusion training may slightly increase training time.
- Evaluated only on two Med-VQA datasets (VQA-RAD and PathVQA) with simulated rather than real annotator noise.
Experimental setup
Datasets: VQA-RAD PathVQA
Benchmarks: VQA-RAD PathVQA
Metrics: accuracy (open, close, overall)
Baselines: MMBERT Q2ATransformer SimT CoDis SNLC Baseline (Swin+BERT+decoder)
Builds on: SNLC CARD Q2ATransformer MMBERT CoDis
Closest papers by meaning
- Alignment, Mining and Fusion: Representation Alignment with Hard Negative Mining and Selective Knowledge Fusion for Medical Visual Question Answering (CVPR 2025 · similarity 0.91)
- Falcon Medical Visual Question Answering (AAAI 2025 · similarity 0.90)
- Fine-grained Adaptive Visual Prompt for Generative Medical Visual Question Answering (AAAI 2025 · similarity 0.89)
- OmniMedVQA: A New Large-Scale Comprehensive Evaluation Benchmark for Medical LVLM (CVPR 2024 · similarity 0.89)
- Visual and Domain Knowledge for Professional-level Graph-of-Thought Medical Reasoning (ICML 2025 · similarity 0.88)
- Detecting Any instruction-to-answer interaction relationship:Universal Instruction-to-Answer Navigator for Med-VQA (ICML 2024 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.