atlas

Research map / Label-efficient and robust learning / Self-supervised and contrastive

BOE-ViT: Boosting Orientation Estimation with Equivariance in Self-Supervised 3D Subtomogram Alignment

CVPR 2025 · Label-efficient and robust learning › Self-supervised and contrastive · approach: Pretext-task visual pre-training · 0 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes BOE-ViT, a self-supervised Vision Transformer for 3D subtomogram alignment that adds shift-equivariant Polyshift and rotation-equivariant MARE modules to estimate rotation and translation under low SNR.

Problem

Subtomogram alignment in cryo-ET requires estimating 3D rotation and translation from very noisy (SNR 0.01–0.1) volumes with few labels, and standard ViTs lack shift and rotation equivariance needed for accurate orientation estimation.

Approach

Self-supervised training that predicts synthetic rigid transformations applied to subtomograms, with a ViT augmented by Polyshift (polyphase anchoring plus circularly padded depthwise-conv positional encoding) for shift equivariance and MARE (axis-wise learnable skew-symmetric rotations applied to queries and keys) for rotation equivariance.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use BOE-ViT rather than Gum-NetSubtomogram alignment · Subtomogram alignment (all datasets), SNR 0.01rotation error: 1.50±0.78 -> 0.34±0.15Helped
Use BOE-ViT rather than Gum-NetSubtomogram alignment · Subtomogram alignment (all datasets), SNR 0.01translation error: 6.78±4.22 -> 2.54±0.91Helped
Add Polyshift (ablation)BOE-ViT · Subtomogram alignment, SNR 0.01translation error: 6.20±1.78 -> 2.32±0.80Helped
Add MARE (ablation)BOE-ViT · Subtomogram alignment, SNR 0.01rotation error: 0.35±0.15 -> 0.33±0.15Helped
Add MARE (ablation)BOE-ViT · Subtomogram alignment, SNR 0.01translation error: 2.62±0.91 -> 2.32±0.80Helped
Use self-attention rather than cross-attention (ablation)BOE-ViT · Subtomogram alignment, SNR 0.01translation error: 3.63±1.78 -> 2.32±0.80Helped

Surprising findings

Limitations

Experimental setup

Datasets: simulated cryo-ET subtomograms for 5LQW, 1I6V, 6A5L, 5T2C, 5MPA

Benchmarks: simulated subtomogram alignment datasets at SNR 0.1, 0.05, 0.03, 0.01 for five macromolecular complexes

Metrics: rotation error translation error

Baselines: H-T align F&A align Gum-Net Jim-Net CrossViT SelfViT

Builds on: Vision Transformer rotary position encoding adaptive polyphase sampling Gum-Net Jim-Net

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy