atlas

Research map / Detection and segmentation / Open-set and few-shot detection

Bi-level Learning of Task-Specific Decoders for Joint Registration and One-Shot Medical Image Segmentation

CVPR 2024 · Detection and segmentation › Open-set and few-shot detection · approach: Few-shot segmentation · 23 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes Bi-JROS, a bi-level optimization framework with a frozen pretrained shared encoder and task-specific registration/segmentation decoders, plus an appearance conformity constraint for one-shot brain MRI segmentation.

Problem

One-shot medical image segmentation via joint registration and segmentation suffers from unstable training due to naive joint or alternating optimization of task-specific decoders, and from appearance mismatch between labeled and unlabeled data used for augmentation.

Approach

Model registration decoder as the upper-level leader and segmentation decoder as the lower-level follower in a bi-level optimization with an implicit-function-based gradient response algorithm, using a frozen pretrained shared encoder and an appearance conformity constraint that warps the fake-labeled image via bidirectional deformations instead of the labeled image.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use Bi-JROS instead of BRBSone-shot medical image segmentation · Mixed datasetSegmentation Dice (%): 81.8 ± 2.4 -> 82.8 ± 2.2Helped
use Bi-JROS instead of BRBSjoint registration and segmentation · Mixed datasetRegistration Dice (%): 80.0 ± 2.4 -> 80.8 ± 2.0Helped
use Bi-JROS instead of SSTimage registration · Mixed datasetNCC: 0.364 ± 0.005 -> 0.387 ± 0.007Helped
use Bi-JROS instead of BRBSone-shot medical image segmentation · OASISSegmentation Dice (%): 80.3 ± 1.1 -> 81.4 ± 0.6Helped
use Bi-JROS instead of BRBSimage registration · OASISRegistration Dice (%): 79.5 ± 1.0 -> 80.0 ± 0.6Helped
use Bi-JROS instead of naive alternative trainingimage registration · OASISNCC: 0.356 ± 0.004 -> 0.362 ± 0.004Helped
freeze the encoder and alternately train the two decoders instead of joint training (ablation)Bi-JROS · Mixed datasetRegistration Dice (%): 79.1 ± 2.0 -> 79.8 ± 2.0; 0.7%Helped
add the appearance conformity constraint (ACC) (ablation)Bi-JROS with a frozen encoder and alternating decoder training · Mixed datasetSegmentation Dice (%): 81.5 ± 1.9 -> 82.1 ± 2.1; 0.6%Helped
add bi-level optimization with Gradient Response (ablation)Bi-JROS with ACC · Mixed datasetRegistration Dice (%): 80.2 ± 2.1 -> 80.8 ± 2.0; 0.6%Helped
add bi-level optimization with Gradient Response (ablation)Bi-JROS with ACC · Mixed datasetSegmentation Dice (%): 82.1 ± 2.1 -> 82.8 ± 2.2; 0.7%Helped

Limitations

Experimental setup

Datasets: ABIDE ADNI PPMI OASIS

Benchmarks: mixed brain MRI dataset (ABIDE, ADNI, PPMI) OASIS

Metrics: Dice NCC

Baselines: SyN NiftyReg deedsBCV VoxelMorph LKU-Net TransMorph UNet MASSL CPS SST DeepAtlas DataAug

Builds on: BRBS UReSNet DataAug VoxelMorph

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy