Adapts CLIP (ViT-L/14) for zero-/few-shot medical anomaly classification and segmentation by inserting multi-level residual adapters trained with pixel-wise visual-language alignment losses, combined with zero-shot text comparison and few-shot memory-bank comparison.

Problem

Zero- and few-shot anomaly detection in medical images fails to transfer from natural-image vision-language models because of large domain shift between natural and medical modalities and anatomical regions.

Approach

Lightweight residual bottleneck adapters are inserted at multiple stages of a frozen CLIP visual encoder and trained with multi-level pixel-wise and image-level visual-language alignment losses against normal/abnormal text prompts, so the backbone is adapted rather than just projected; at test time zero-shot text comparison is fused with few-shot memory-bank nearest-neighbour scores.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
adapt CLIP with multi-level feature adapters rather than independently optimized multi-level projectors (ablation)CLIP ViT-L/14 · Medical zero-shot benchmarksAC AUC: +13.57% average improvementHelped
adapt CLIP with multi-level feature adapters rather than independently optimized multi-level projectors (ablation)CLIP ViT-L/14 · BrainMRI, LiverCT, RESCAS AUC: 0.88%, 0.21%, and 2.88%Helped
combine features from all layers instead of using an individual layer (ablation)MVFA · Medical few-shot (K=4)AC AUC: 88.97 vs 88.84Helped
combine features from all layers instead of using an individual layer (ablation)MVFA · Medical few-shot (K=4)AS AUC: 98.67 vs 98.62Helped
train with multi-level rather than single-layer adapters (ablation)MVFA · Medical few-shot (K=4)AC and AS AUCHelped
use multi-level adapters for zero-shot medical anomaly detection instead of APRIL-GANCLIP-based medical AD · Medical benchmarksAC AUC: 6.24% average improvementHelped
use multi-level adapters for zero-shot medical anomaly detection instead of APRIL-GANCLIP-based medical AD · Medical benchmarksAS AUC: 2.03% average improvementHelped
use multi-level adapters for few-shot medical anomaly detection instead of APRIL-GANCLIP-based medical AD · Medical benchmarksAC AUC: 7.33% average improvementHelped
use multi-level adapters for few-shot medical anomaly detection instead of APRIL-GANCLIP-based medical AD · Medical benchmarksAS AUC: 2.37% average improvementHelped

Surprising findings

Limitations

Experimental setup

Datasets: BrainMRI LiverCT RESC OCT17 ChestXray HIS BMAD MVTec AD

Benchmarks: BrainMRI LiverCT RESC OCT17 ChestXray HIS MVTec AD

Metrics: AUC

Baselines: CFlowAD RD4AD PatchCore MKD CLIP MedCLIP WinCLIP DRA BGAD APRIL-GAN

Builds on: CLIP WinCLIP APRIL-GAN AdaptFormer-style residual adapters