Measured effects reported in the paper

What was changedWhereMeasuredEffect
Train R50 and ViT-B collaboratively with MOKD instead of independentlyR50 and ViT-B · ImageNet vallinear probing accuracy: 72.1 -> 75.6 (R50); 77.0 -> 78.0 (ViT-B)Improved
Train R50 and ViT-B collaboratively with MOKD instead of independentlyR50 and ViT-B · ImageNet valk-NN accuracy: 62.8 -> 70.6 (R50); 73.6 -> 75.2 (ViT-B)Improved
Use MOKD rather than the strongest listed SSL-KD baseline DisCoR34 with R50 teacher · ImageNet vallinear probing accuracy: 62.5 -> 67.0Improved
Use MOKD rather than independent pre-trainingR50 with ViT-B · ImageNet 1% subsettop-1 accuracy: 49.5 -> 57.2Improved
Use MOKD rather than independent pre-trainingR50 with ViT-S · CIFAR-100top-1 accuracy: 85.3 -> 86.2Improved
Use MOKD rather than DisCo pre-trainingR34 with R50 teacher · COCO val2017detection APᵇ: 40.0 -> 40.3Improved
Add cross-distillation L_cm to self-distillation L_sm (ablation)MOKD, R50 and ViT-S · ImageNet100 vallinear probing top-1 accuracy: 87.0 -> 87.2 (R50); 80.3 -> 82.6 (ViT-S)Improved
Add T-Head self-distillation L_st (ablation)MOKD, R50 and ViT-S · ImageNet100 vallinear probing top-1 accuracy: 87.2 -> 87.7 (R50); 82.6 -> 83.5 (ViT-S)Improved
Add T-Head cross-distillation L_ct (ablation)MOKD, R50 and ViT-S · ImageNet100 vallinear probing top-1 accuracy: 87.7 -> 88.3 (R50); 83.5 -> 84.6 (ViT-S)Improved
Increase T-Head depth from one to three transformer blocks (ablation)MOKD, R50 and ViT-S · ImageNet100 vallinear probing top-1 accuracy: 87.4, 83.3 -> 88.3, 84.6Improved
Increase cross-distillation weight for the stronger R50 while keeping ViT-S weight at 1 (ablation)MOKD, R50-ViT-S · ImageNet100 vallinear probing top-1 accuracy: 88.3 -> 87.4 (R50); 84.6 -> 84.1 (ViT-S)Hurt
Increase cross-distillation weight for the weaker ViT-S while keeping R50 weight at 0.1 (ablation)MOKD, R50-ViT-S · ImageNet100 vallinear probing top-1 accuracy: 80.4 -> 84.6 (ViT-S)Improved