Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use HRDFuse with 256×256 TP patches instead of OmniFusion (2-iter)360° monocular depth estimation · 3D60Abs Rel: 0.0430 -> 0.0358Improved
Use HRDFuse with 256×256 TP patches instead of OmniFusion (2-iter)360° monocular depth estimation · Stanford2D3DAbs Rel: 0.0950 -> 0.0935Improved
Use HRDFuse with 128×128 TP patches instead of PanoFormer360° monocular depth estimation · Matterport3DAbs Rel: 0.0904 -> 0.0967Hurt
Combine ERP and TP branches, then add SFA instead of geometric fusion (ablation)HRDFuse · Matterport3DFPS: 2.82 -> 6.21Improved
Add CDDC to the ERP+TP model with SFA (ablation)HRDFuse · Matterport3DAbs Rel: 0.0991 -> 0.0967Improved
Use only the ERP branch rather than combining ERP and TP (ablation)HRDFuse · Matterport3DAbs Rel: 0.0967 -> 0.1028Hurt
Use 46 rather than 18 TP patches with 128×128 patches (ablation)HRDFuse · Matterport3DAbs Rel: 0.0967 -> 0.1232Hurt
Use 46 rather than 18 TP patches with 256×256 patches (ablation)HRDFuse · Matterport3DAbs Rel: 0.0981 -> 0.0966Improved
Reduce TP patch FoV from 80° to 60° (ablation)HRDFuse with 128×128 TP patches · Matterport3DAbs Rel: 0.0967 -> 0.0986Hurt
Increase TP patch FoV from 80° to 100° (ablation)HRDFuse with 128×128 TP patches · Matterport3DAbs Rel: 0.0967 -> 0.0970Hurt
Use 100 rather than 20 depth histogram bins (ablation)HRDFuse · Matterport3DAbs Rel: 0.0997 -> 0.0967Improved
Increase depth histogram bins from 100 to 150 (ablation)HRDFuse · Matterport3DAbs Rel: 0.0967 -> 0.0997Hurt

Later papers that compared with this method

3 later accepted papers report HRDFuse as a baseline in their results tables; 3 of them report a better number on most of the results they share with it.

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 0 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy