Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Replace a similarly sized ResNet base classifier with a ViT in derandomized smoothing | Smoothed image classifiers · ImageNet, 2% pixels | certified accuracy: 18.3 -> 31.6 | Helped |
| Replace a ResNet base classifier with a ViT in derandomized smoothing | Smoothed image classifiers · CIFAR-10, 4×4 patch | certified accuracy: 59.0 -> 63.8 | Helped |
| Increase test-time column ablation width from b = 19 to b = 37 (ablation) | ViT-B smoothed classifier · ImageNet | standard accuracy: 69.3 -> 73.2 | Helped |
| Increase test-time column ablation width from b = 19 to b = 37 (ablation) | ViT-B smoothed classifier · ImageNet, 2% pixels | certified accuracy: 38.3 -> 38.2 | No clear effect |
| Increase test-time column ablation width from b = 19 to b = 25 (ablation) | ViT-B smoothed classifier · ImageNet, 2% pixels | certified accuracy: 38.3 -> 38.8 | Helped |
| Use stride s = 10 for column ablations (ablation) | ViT-B smoothed classifier · ImageNet, 2% pixels | certified accuracy: 38.3 -> 36.9 | Hurt |
| Use stride s = 10 for column ablations (ablation) | ViT-B smoothed classifier · ImageNet | inference time: 31.5 -> 3.2 sec | Helped |
| Increase training-time column ablation width for ViT-S to b = 37 instead of b = 19 (ablation) | ViT-S smoothed classifier · ImageNet | certified accuracy: 1.3% | Helped |
| Increase training-time column ablation width for ResNet-50 to b = 37 (ablation) | ResNet-50 smoothed classifier · ImageNet | certified accuracy: 18% to 27% | Helped |
| Drop tokens corresponding to fully masked image regions (ablation) | Vision Transformer base classifier · ImageNet and CIFAR-10 image ablations | ablation accuracy | No clear effect |
| Drop fully masked tokens during smoothing (ablation) | ViT smoothed classifier · ImageNet, b = 19 | inference speedup over smoothed ResNets: 5.85x; 10.68x; 22.04x | Helped |
| Use block ablations instead of column ablations (ablation) | ViT-B smoothed classifier · ImageNet | certified accuracy: up to 5% | Hurt |
Closest papers by meaning
- Improving Robustness of Vision Transformers by Reducing Sensitivity To Patch Corruptions (CVPR 2023 · similarity 0.90)
- Towards Practical Certifiable Patch Defense With Vision Transformer (CVPR 2022 · similarity 0.90)
- Mitigating the Curse of Dimensionality for Certified Robustness via Dual Randomized Smoothing (ICLR 2024 · similarity 0.85)
- An Image is Worth More Than 16x16 Patches: Exploring Transformers on Individual Pixels (ICLR 2025 · similarity 0.84)
- Improving Interpretation Faithfulness for Vision Transformers (ICML 2024 · similarity 0.84)
- Pixel-level Certified Explanations via Randomized Smoothing (ICML 2025 · similarity 0.83)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.