Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use input-only zero-shot learning with pre-upsampling, view alignment, and multi-view aggregationLight field SR · Stan, EPFL, HCI1, and HCI2, scale 2PSNR (dB): 37.91 vs 37.03; 34.51 vs 34.00; 39.74 vs 38.86; 37.75 vs 37.08Helped
Use zero-shot SR rather than the strongest reported source-trained deep baselineLight field SR · Stan, EPFL, HCI1, and HCI2, scale 2PSNR (dB): 37.91 vs 37.92; 34.51 vs 34.45; 39.74 vs 39.60; 37.75 vs 37.82Mixed
Apply error-guided fine-tuning to the source-pretrained modelLight field SR · Stan, EPFL, HCI1, and HCI2, scale 2, SAE sourcePSNR (dB): 37.36 -> 37.97; 34.29 -> 34.64; 39.42 -> 39.98; 37.56 -> 37.85Helped
Apply error-guided fine-tuning to the source-pretrained modelLight field SR · Stan, EPFL, HCI1, and HCI2, scale 2, HFUT sourcePSNR (dB): 37.55 -> 38.27; 34.55 -> 35.21; 39.42 -> 40.38; 37.22 -> 38.22Helped
Use error-guided rather than plain fine-tuning (ablation)Ours-FT · Stanford and HCI2, scale 2PSNR (dB): about 0.4 dBHelped
Divide SR into sub-tasks instead of using an end-to-end network (ablation)Zero-shot light field SR · StanfordPSNR (dB): 2.75/1.81/1.97 dBHelped
Replace VDSR pre-upsampling with bicubic interpolation (ablation)Zero-shot light field SR · Stanford and HCI2, scale 2PSNR (dB)Hurt
Remove view alignment before aggregation (ablation)Zero-shot light field SR · Stanford and HCI2, scale 2PSNR (dB): 0.73/0.62 dBHurt
Remove the back-projection loss (ablation)AggreNet in zero-shot light field SR · Stanford and HCI2, scale 2PSNR (dB): 0.22/0.25 dBHurt
Remove the joint training stage (ablation)Zero-shot light field SR · Stanford and HCI2, scale 2PSNR (dB): about 0.2 dBHurt