Research map / 3D vision / Human pose estimation
Epipolar Transformers
Check your idea against 108,967 papers
AI-extracted summary. Written by AI from the paper's title only (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Add epipolar-transformer feature fusion | Hourglass 2D detector · InterHand test | MPJPE (mm): 5.46 -> 4.91 | Helped |
| Add epipolar-transformer feature fusion | ResNet-50 pose detector · Human3.6M test | JDR (%): 95.9 -> 97.01 | Helped |
| Add rotation and scaling data augmentation | Epipolar transformer with ResNet-50 · Human3.6M test | JDR (%): 97.01 -> 98.25 | Helped |
| Add epipolar-transformer feature fusion | ResNet-50 with triangulation · Human3.6M test, no external data | MPJPE (mm): 48.7 -> 33.1 | Helped |
| Replace global cross-view fusion with epipolar-transformer fusion | ResNet-50 with triangulation · Human3.6M test, no external data | MPJPE (mm): 45.5 -> 33.1 | Helped |
| Use RPSM instead of triangulation for 3D pose estimation | ResNet-50 with epipolar transformer · Human3.6M test, no external data | MPJPE (mm): 33.1 -> 26.9 | Helped |
| Use rotation and scaling augmentation | ResNet-50 with epipolar transformer and triangulation · Human3.6M test, no external data | MPJPE (mm): 33.1 -> 30.4 | Helped |
| Use Identity Gaussian rather than Bottleneck Embedded Gaussian fusion (ablation) | Epipolar transformer · InterHand test | MPJPE (mm): 4.99 -> 4.91 | Helped |
| Use softmax rather than max for epipolar attention (ablation) | Epipolar transformer · InterHand test | MPJPE (mm): 4.97 -> 4.91 | Helped |
| Use Identity Gaussian rather than Bottleneck Embedded Gaussian fusion (ablation) | Epipolar transformer · Human3.6M test | MPJPE (mm): 35.7 -> 33.1 | Helped |
| Insert the transformer at the early stage rather than the late stage (ablation) | Hourglass epipolar-transformer detector · InterHand test | MPJPE (mm): 4.91 -> 4.96 | No clear effect |
| Insert the transformer at both early and late stages (ablation) | Hourglass epipolar-transformer detector · InterHand test | MPJPE (mm): 4.91 -> 5.03 | Hurt |
Closest papers by meaning
- Multiple View Geometry Transformers for 3D Human Pose Estimation (CVPR 2024 · similarity 0.85)
- Neural Localizer Fields for Continuous 3D Human Pose and Shape Estimation (NeurIPS 2024 · similarity 0.84)
- SVTformer: Spatial-View-Temporal Transformer for Multi-View 3D Human Pose Estimation (AAAI 2025 · similarity 0.84)
- Epipolar-Free 3D Gaussian Splatting for Generalizable Novel View Synthesis (NeurIPS 2024 · similarity 0.84)
- ExtPose: Robust and Coherent Pose Estimation by Extending ViTs (ICML 2025 · similarity 0.84)
- EpiDiff: Enhancing Multi-View Synthesis via Localized Epipolar-Constrained Diffusion (CVPR 2024 · similarity 0.84)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
