Measured effects reported in the paper

What was changedWhereMeasuredEffect
use PET instead of purely supervised trainingRoBERTa-base · Exaggeration detection, T1 (paired sentences, 100 labeled pairs), testmacro F1: 29.05 -> 39.12Improved
add auxiliary T2 claim-strength task (MT-PET) to PET (ablation)PET (T1 main) · Exaggeration detection, T1 (paired sentences, 100 labeled pairs), testmacro F1: 39.12 -> 47.35Improved
use PET instead of supervised training (200 T2 instances)RoBERTa-base · Exaggeration detection via strength classification, T2 (200 T2 instances), testmacro F1: 49.03 -> 56.57Improved
add auxiliary T1 exaggeration task (MT-PET) to PET (200 T2) (ablation)PET (T2 main) · Exaggeration detection via strength classification, T2 (200 T2 instances), testmacro F1: 56.57 -> 57.44Improved
add auxiliary T1 task (MT-PET) to PET with 4500 T2 instances (ablation)PET (T2 main) · Exaggeration detection via strength classification, T2 (4500 T2 instances), testmacro F1: 60.45 -> 61.11Improved
use MT-PET with 4500 T2 instances for press-release claim strength (ablation)PET (T2 main) · Exaggeration detection via strength classification, T2 (4500 T2 instances), test - press releaseF1: 64.20 -> 63.93Hurt
MT-PET with 200 T2 + 100 T1 vs supervised with 4500 T2MT-PET · Exaggeration detection via strength classification, T2 (200 T2 instances), testmacro F1: 57.44 vs 58.66No clear effect
add in-domain MLM on T1 data to PET (200 T2) (ablation)PET (T2 main) · Exaggeration detection via strength classification, T2 (200 T2 instances), testmacro F1: 56.57 -> 58.06Improved
MT-PET vs PET + in-domain MLM (200 T2) (ablation)MT-PET · Exaggeration detection via strength classification, T2 (200 T2 instances), testmacro F1: 58.06 -> 57.44 (MLM higher on overall F1; MT-PET higher on press/abstract F1 64.72 vs 64.29, 63.27 vs 62.69)Mixed
use T2 (claim strength comparison) instead of T1 (direct inference) formulationMT-PET · Exaggeration detection, T1 (paired sentences, 100 labeled pairs), testmacro F1: 47.35 (T1) -> 57.44 (T2, 200)Improved