Research map / Label-efficient and robust learning / OOD and anomaly detection
GOLD: Improving Out-of-Scope Detection in Dialogues using Data Augmentation
Read the paperPlace an idea next to itCheck your own paper ↗
11measured effects
7improved
4hurt
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| train detector on GOLD-augmented pseudo-OOS data (GloVe extraction) instead of indirect baselines | BERT OOS detector · STAR test | AUROC / AUPR: AUROC 0.8002 -> 0.8683; AUPR 0.3179 -> 0.4450 | Improved |
| train on GOLD-augmented data (GloVe) instead of best indirect baseline | BERT OOS detector · FLOW test | AUROC / AUPR: AUROC 0.7223 -> 0.8022; AUPR 0.1887 -> 0.3243 | Improved |
| train on GOLD-augmented data (GloVe) instead of best indirect baseline | BERT OOS detector · ROSTD test | AUROC / FPR@0.95: AUROC 0.9821 -> 0.9990; FPR@.95 7.97% -> 0.17% | Improved |
| use Paraphrase (most similar) extraction instead of GloVe (ablation) | GOLD · STAR, FLOW, ROSTD test | AUROC: STAR 0.8683 -> 0.8537; FLOW 0.8022 -> 0.7767; ROSTD 0.9990 -> 0.9967 | Hurt |
| use Random extraction instead of GloVe extraction (ablation) | GOLD · STAR, FLOW, ROSTD test | AUROC: STAR 0.8683 -> 0.8531; FLOW 0.8022 -> 0.7692; ROSTD 0.9990 -> 0.9984 | Hurt |
| add augmented pseudo-labeled examples (up to about 24 matches per seed) (ablation) | GOLD · STAR, FLOW, ROSTD | AUROC | Improved |
| add the election filtering step (ablation) | GOLD (GloVe, QQP source) · STAR / FLOW / ROSTD | AUROC (as captioned): STAR 0.2487 -> 0.3885; FLOW 0.2548 -> 0.3173; ROSTD 0.9312 -> 0.9884 | Improved |
| halve the seed set while doubling matches (24 -> 48) (ablation) | GOLD · STAR / FLOW / ROSTD | AUROC (as captioned): STAR 0.3885 -> 0.1983; FLOW 0.3173 -> 0.2111; ROSTD 0.9884 -> 0.8856 | Hurt |
| swap any user utterance rather than only the last one (ablation) | GOLD candidate generation · STAR / FLOW / ROSTD | AUROC (as captioned): STAR 0.3678 -> 0.3885; FLOW 0.2980 -> 0.3173; ROSTD 0.9656 -> 0.9884 | Improved |
| use medical QA or unlabeled target samples as source instead of QQP (ablation) | GOLD · STAR / FLOW / ROSTD | AUROC (as captioned): STAR 0.3885 -> 0.2722 (MQA), 0.2186 (US) | Hurt |
| use mixed source datasets (MIX) rather than single source (ablation) | GOLD · all three datasets | AUROC | Improved |
Closest papers by meaning
- Navigating the Unknown: Intent Classification and Out-of-Distribution Detection Using Large Language Models (EMNLP 2025 · similarity 0.87)
- MIntRec2.0: A Large-scale Benchmark Dataset for Multimodal Intent Recognition and Out-of-scope Detection in Conversations (ICLR 2024 · similarity 0.87)
- Likelihood Ratios and Generative Classifiers for Unsupervised Out-of-Domain Detection in Task Oriented Dialog (AAAI 2020 · similarity 0.86)
- Unsupervised End-to-End Task-Oriented Dialogue with LLMs: The Power of the Noisy Channel (EMNLP 2024 · similarity 0.86)
- SuperDialseg: A Large-scale Dataset for Supervised Dialogue Segmentation (EMNLP 2023 · similarity 0.85)
- Revisiting Mahalanobis Distance for Transformer-Based Out-of-Domain Detection (AAAI 2021 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.