Research map / Vision-language and multimodal / CLIP and zero-shot
Prompting ELECTRA: Few-Shot Learning with Discriminative Pre-Trained Models
Mengzhou Xia, Mikel Artetxe, Jingfei Du, Danqi Chen, Ves Stoyanov
Princeton University · Meta
Read the paperPlace an idea next to itCheck your own paper ↗
14measured effects
6improved
2no clear effect
5hurt
1mixed
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use ELECTRA instead of RoBERTa for prompt-based few-shot fine-tuning | prompt-based fine-tuning · 9 single-token tasks (base) | average accuracy: +3.1 points on average (vs BERT +10.2) | Improved |
| use ELECTRA instead of RoBERTa for prompt-based zero-shot prediction | prompt-based zero-shot · 9 single-token tasks (base) | average accuracy: +3.5 points on average (vs BERT +7.9) | Improved |
| add prompts to standard fine-tuning (ablation) | ELECTRA-base few-shot · SST-2 | accuracy: 78.2 -> 91.2 | Improved |
| use ELECTRA instead of RoBERTa with standard few-shot fine-tuning | standard few-shot fine-tuning · 9 single-token tasks (base) | average accuracy: +1.1 points on average (vs BERT +3.1) | Improved |
| use ELECTRA instead of RoBERTa | few-shot fine-tuning · AGNews | accuracy: 87.1 (RoBERTa) vs 86.9 (ELECTRA) | No clear effect |
| use ELECTRA instead of RoBERTa | zero-shot prompt · AGNews | accuracy: 73.2 -> 72.2 | Hurt |
| use ELECTRA instead of RoBERTa | standard few-shot fine-tuning · SST-2 | accuracy: 84.5 -> 78.2 | Hurt |
| use ELECTRA instead of RoBERTa-PET for multi-token options | 32-shot multiple-choice (base) · COPA, StoryCloze, HellaSwag, PIQA | accuracy: StoryCloze 69.8 -> 86.6; COPA 78.1 -> 76.7 | Mixed |
| use average token representation instead of [CLS] on large ELECTRA (ablation) | ELECTRA-large multiple choice · COPA | accuracy: 96.0 -> 88.7 | Hurt |
| use average token representation instead of [CLS] on base ELECTRA (ablation) | ELECTRA-base multiple choice · StoryCloze | accuracy: 84.5 -> 86.6 | Improved |
| replace original ELECTRA objective with contrastive objective (ablation) | ELECTRA-base prompt few-shot · AGNews (K=16) | accuracy: 86.5 -> 85.4 | Hurt |
| remove data shuffling from original objective (ablation) | ELECTRA-base prompt few-shot · AGNews (K=32) | accuracy: 88.4 -> 86.5 | Hurt |
Closest papers by meaning
- Automated Few-Shot Classification with Instruction-Finetuned Language Models (EMNLP 2023 · similarity 0.89)
- Tuning Language Models as Training Data Generators for Augmentation-Enhanced Few-Shot Learning (ICML 2023 · similarity 0.89)
- Towards Unified Prompt Tuning for Few-shot Text Classification (EMNLP 2022 · similarity 0.89)
- ELECTRA: Pre-training Text Encoders as Discriminators Rather Than Generators (ICLR 2020 · similarity 0.88)
- Fast-ELECTRA for Efficient Pre-training (ICLR 2024 · similarity 0.88)
- Many-Shot In-Context Learning (NeurIPS 2024 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
