AI Paper Atlas

Research map / Vision-language and multimodal / CLIP and zero-shot

Prompting ELECTRA: Few-Shot Learning with Discriminative Pre-Trained Models

Mengzhou Xia, Mikel Artetxe, Jingfei Du, Danqi Chen, Ves Stoyanov

EMNLP 2022Vision-language and multimodal › CLIP and zero-shotapproach: Prompt learning for CLIP23 citations (OpenAlex)

Princeton University · Meta

Read the paperPlace an idea next to itCheck your own paper ↗

14measured effects
6improved
2no clear effect
5hurt
1mixed

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use ELECTRA instead of RoBERTa for prompt-based few-shot fine-tuningprompt-based fine-tuning · 9 single-token tasks (base)average accuracy: +3.1 points on average (vs BERT +10.2)Improved
use ELECTRA instead of RoBERTa for prompt-based zero-shot predictionprompt-based zero-shot · 9 single-token tasks (base)average accuracy: +3.5 points on average (vs BERT +7.9)Improved
add prompts to standard fine-tuning (ablation)ELECTRA-base few-shot · SST-2accuracy: 78.2 -> 91.2Improved
use ELECTRA instead of RoBERTa with standard few-shot fine-tuningstandard few-shot fine-tuning · 9 single-token tasks (base)average accuracy: +1.1 points on average (vs BERT +3.1)Improved
use ELECTRA instead of RoBERTafew-shot fine-tuning · AGNewsaccuracy: 87.1 (RoBERTa) vs 86.9 (ELECTRA)No clear effect
use ELECTRA instead of RoBERTazero-shot prompt · AGNewsaccuracy: 73.2 -> 72.2Hurt
use ELECTRA instead of RoBERTastandard few-shot fine-tuning · SST-2accuracy: 84.5 -> 78.2Hurt
use ELECTRA instead of RoBERTa-PET for multi-token options32-shot multiple-choice (base) · COPA, StoryCloze, HellaSwag, PIQAaccuracy: StoryCloze 69.8 -> 86.6; COPA 78.1 -> 76.7Mixed
use average token representation instead of [CLS] on large ELECTRA (ablation)ELECTRA-large multiple choice · COPAaccuracy: 96.0 -> 88.7Hurt
use average token representation instead of [CLS] on base ELECTRA (ablation)ELECTRA-base multiple choice · StoryClozeaccuracy: 84.5 -> 86.6Improved
replace original ELECTRA objective with contrastive objective (ablation)ELECTRA-base prompt few-shot · AGNews (K=16)accuracy: 86.5 -> 85.4Hurt
remove data shuffling from original objective (ablation)ELECTRA-base prompt few-shot · AGNews (K=32)accuracy: 88.4 -> 86.5Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy