AI Paper Atlas

Research map / Large language models / Language, safety and interpretability

BioReader: a Retrieval-Enhanced Text-to-Text Transformer for Biomedical Literature

Giacomo Frisoni, Miki Mizutani, Gianluca Moro, Lorenzo Valgimigli

EMNLP 2022 · Large language models › Language, safety and interpretability · approach: Controlled text generation · 55 citations (OpenAlex) · University of Bologna

Read the paper

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add retrieval (BioReader) over SciFive-baseSciFive-base · MedQA-USMLEExact Match: 34.57 -> 42.96Improved
BioReader (229.5M) vs 3x larger SciFive-largeSciFive-large · MedQA-USMLEExact Match: 35.12 -> 42.96Improved
add retrieval (BioReader) over SciFive-baseSciFive-base · MedQA-USMLEhuman-evaluated scientific accuracy: 38.03 -> 48.57Improved
add retrieval (BioReader) over SciFive-baseSciFive-base · QA and OpenQA (human eval)fluency (avg, 1-3): 2.49 -> 2.86Improved
add retrieval (BioReader) over SciFive-baseSciFive-base · HoC testF1 (sample average): 85.89 -> 87.78Improved
add retrieval (BioReader) over SciFive-baseSciFive-base · ChemProt testF1: 88.83 -> 88.16Hurt
add retrieval (BioReader) over SciFive-baseSciFive-base · MedNLI testaccuracy: 85.30 -> 85.76No clear effect
retrieve neighbors plus their continuation (N + F) instead of neighbors only (ablation)BioReader · ChemProt (ablation subset)F1: 80.79 -> 84.96Improved
retrieve neighbors plus their continuation (N + F) instead of neighbors only (ablation)BioReader · MedNLI (ablation subset)accuracy: 76.54 -> 52.63Hurt
use Contriever instead of SciFive encoder for retrieval keys and queries (ablation)BioReader · HoC (ablation subset)F1 (sample average): 64.70 -> 77.06Improved
use Contriever instead of SciFive encoder for retrieval keys and queries (ablation)BioReader · DDI (ablation subset)F1: 64.70 -> 49.91Hurt
place CCA layers in decoder instead of encoder-only (ablation)BioReader · downstream ablation tasksF1 / accuracyImproved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy