AI Paper Atlas

Research map / Vision-language and multimodal / CLIP and zero-shot

BERTwich: Extending BERT's Capabilities to Model Dialectal and Noisy Text

Aarohi Srivastava, David Chiang

EMNLP 2023Vision-language and multimodal › CLIP and zero-shotapproach: Language models for zero-shot reasoning13 citations (OpenAlex)

University of Notre Dame

Read the paperPlace an idea next to itCheck your own paper ↗

12measured effects
9improved
1no clear effect
2hurt

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add noise to fine-tuning data (40% vs 0%) (ablation)BERT, no CPT · SST noisy testaccuracy: 51.5 -> 65.6Improved
add continued pre-training on noised Wikipedia (ablation)BERT · SST noisy test (0% fine-tune noise)accuracy: 51.5 -> 56.4Improved
add L0 + CPT to BERT (ablation)BERT + CPT · SST noisy test (40% noise)accuracy: 73.6 -> 74.7Improved
add L0 and LF layers + CPT (ablation)BERT · South Tyrolean intent classification (0% noise)accuracy: 79.9 -> 83.3Improved
add L0 and LF layers + CPT versus noise-fine-tuned BERT (ablation)BERT · South Tyrolean intent classification (40% noise)accuracy: 95.0 -> 97.9Improved
add CPT with added layers (no fine-tuning noise) (ablation)BERT · Swiss German intent classification (0% noise)accuracy: 59.7 -> 74.5Improved
add CPT with added layers with fine-tuning noise (ablation)BERT · Swiss German intent classification (40% noise)accuracy: 87.9 -> 85.3Hurt
place both extra layers on top (BERT + LFx2) instead of sandwich (ablation)BERTwich · German CLS similarity, South Tyroleancosine similarity: 0.85 -> 0.69Hurt
add L0 + LF layers with CPT (ablation)BERT · word/typo cosine similarity (English, top layer)cosine similarity: 0.24 -> 0.70Improved
use BERTwich instead of LoRA after CPT (ablation)BERT + CPT + LoRA · SST noisy test (40% noise)accuracy: 69.6 (LoRA+CPT) vs 74.7 (L0+BERT, CPT)Improved
add CPT before LoRA (ablation)BERT + LoRA · SST noisy test (0% noise)accuracy: 51.6 -> 58.8Improved
add BERTwich modifications and CPT (ablation)BERT · un-noised SST and standard Germanaccuracy: e.g. SST 91.0 -> 90.8 (L0+BERT+LF+CPT, 0% noise)No clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy