AI Paper Atlas

Research map / Continual learning / Continual fine-tuning of LLMs

Visually Grounded Continual Language Learning with Selective Specialization

EMNLP 2023Continual learning › Continual fine-tuning of LLMsapproach: Mixture-of-experts for multimodal continual tuning5 citations (OpenAlex)

Read the paperPlace an idea next to itCheck your own paper ↗

12measured effects
5improved
2no clear effect
5mixed

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
specialize self-attention modules in all layers (with A&C) (ablation)VL Transformer · LILAC-2D / LILAC-3Daccuracy: SFT 51.1 -> 81.2 (2D); 67.0 -> 81.2 (3D)Improved
combine all-attn specialization with EWC in consolidation (ablation)S_all-attn VL Transformer · LILAC-2Daccuracy: 81.2 -> 87.1Improved
combine all-attn specialization with ER in consolidation (ablation)S_all-attn VL Transformer · LILAC-2D / LILAC-3Daccuracy: 81.2 -> 85.7 (2D); 81.2 -> 88.5 (3D)Improved
use adaptation-consolidation (A&C) instead of joint training (ablation)module specialization strategies · LILAC (per-module accuracy gain)accuracy: positive for all VL transformer modules; majority of FiLM modulesImproved
specialize late rather than early transformer layers (ablation)VL Transformer · LILACaccuracyImproved
specialize FiLM batch normalization parameters (ablation)FiLM · LILAC-2D / LILAC-3DaccuracyMixed
specialize layer normalization parameters (ablation)VL Transformer · LILAC-2D / LILAC-3Daccuracy: more than 5% gain on 3DMixed
specialize only first feed-forward layer (ffn1) instead of whole feed-forward block (ablation)VL Transformer · LILACaccuracyNo clear effect
specialize first-layer / last-layer modules vs baselines (ablation)FiLM and Transformer · LILAC-3Daccuracy: e.g. Transformer first-layer 76.5 vs EWC 79.0Mixed
specialize convolutions in last FiLM layer (ablation)FiLM · LILAC-2D / LILAC-3Daccuracy: SFT 52.1 -> 59.4 (2D); 63.2 -> 62.5 (3D)Mixed
gradient-based importance score as predictor of specialization gain (ablation)module importance · LILAC-2D / LILAC-3Daccuracy: Pearson 0.91/0.90 (2D), 0.09/0.40 (3D) FiLM/TransformerMixed
activation-based importance score as predictor of specialization gain (ablation)module importance · LILACaccuracy: Pearson 2D: 0.48/-0.53, 3D: -0.09/-0.32No clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy