AI Paper Atlas

Research map / Large language models / Language, safety and interpretability

Finding Support Examples for In-Context Learning

Xiaonan Li, Xipeng Qiu

EMNLP 2023Large language models › Language, safety and interpretabilityapproach: In-context learning analysis168 citations (OpenAlex)

Fudan University

Read the paperPlace an idea next to itCheck your own paper ↗

14measured effects
9improved
3no clear effect
1hurt
1mixed

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
replace random in-context examples with LENS support examplesGPT2-L ICL · 8 text classification datasets averageaccuracy: 44.2/54.0 -> 69.8/73.3Improved
use coreset selection methods from gradient-based training instead of random examplesGPT2-L ICL · 8 text classification datasets averageaccuracy: Random 44.2/54.0; best FacilityLocation 49.6/57.7No clear effect
select best of random sets on a validation set (Random & Valid)GPT2-L ICL · 8 text classification datasets averageaccuracy: 44.2/54.0 -> 50.1/51.6 (100), 49.5/55.9 (1000)No clear effect
add random examples versus zero-shotGPT2-L ICL · 8 text classification datasets averageaccuracy: 45.6/50.7 -> 44.2/54.0Mixed
add stage 2 diversity-guided search after filtering (ablation)LENS · Subj / AGNewsaccuracy: 65.8 -> 86.4 (Subj); 47.8 -> 77.9 (AGNews)Improved
filter by high InfoScore instead of random sampling (ablation)LENS stage 1 · Subj / AGNewsaccuracy: 55.0 -> 65.8 (Subj); 33.6 -> 47.8 (AGNews)Improved
keep low-InfoScore (uninformative) examples instead of random (ablation)LENS stage 1 · Subj / AGNewsaccuracy: 55.0 -> 52.5 (Subj); 33.6 -> 27.4 (AGNews)Hurt
set diversity weight lambda from 0 to 1 (ablation)LENS · SST-2accuracy: 67.5 -> 86.3Improved
increase beam size from 1 to 8 (ablation)LENS · SST-2 / Subj / TRECaccuracy: 83.1 -> 86.3 (SST-2); 76.2 -> 86.4 (Subj); 42.2 -> 59.0 (TREC)Improved
retain 500 instead of 50 examples after filtering (ablation)LENS · SST-2 / Subj / TRECaccuracy: 83.6 -> 86.3 (SST-2); 56.2 -> 59.0 (TREC)Improved
change progressive factor p between 1.5, 2 and 3 (ablation)LENS · SST-2 / Subj / TREC averageaccuracy: 77.4 / 77.2 / 76.6No clear effect
use ground-truth labels versus random labels in support examples (ablation)LENS support examples · SST-2, Amazon, MR, Subj (Figure)accuracyImproved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy