Measured effects reported in the paper

What was changedWhereMeasuredEffect
pre-train SBERT-Paraphrase with intent-aware contrastive learning (PIE)SBERT-Paraphrase (paraphrase-mpnet-base-v2) · 4 IC datasets, 5-way 1-shot averageaccuracy: 85.7 -> 88.5Improved
add intent-aware pre-training (L-PIE) with label names as prototypesL-SBERT-Paraphrase · 4 IC datasets, N-way 0-shot / 1-shot averageaccuracy: 68.3 -> 73.7 (0-shot); 78.0 -> 82.0 (1-shot)Improved
fine-tune with ProtoNet on top of pre-trained encoderL-PIE vs L-SBERT-Paraphrase · Banking77, 5-wayaccuracy: L-PIE+ProtoNet 90.7 vs L-SBERT+ProtoNet 90.9 (0-shot)No clear effect
add ProtAugment fine-tuning to L-PIEL-PIE · 4 IC datasets, 5-way 0-shot averageaccuracy: 89.1 -> 91.2Improved
remove L_pseudo from pre-training loss (ablation)L-PIE · Clinc150 N=50, 0-shotaccuracy: 83.1 -> 81.4 when removedImproved
remove L_pseudo from pre-training loss (ablation)L-PIE · HWU64 N=25, 0-shotaccuracy: 68.7 -> 66.9 when removedImproved
remove L_gold_intent from pre-training loss (ablation)L-PIE · HWU64 N=25 / Clinc150 N=50accuracy: HWU64 0-shot 68.7 -> 68.7; Clinc150 1-shot 90.4 -> 90.4; Clinc150 0-shot 83.1 -> 82.7No clear effect
remove L_gold_utterance from pre-training loss (ablation)L-PIE · HWU64 N=25 / Clinc150 N=50accuracy: HWU64 1-shot 76.8 -> 75.9; Clinc150 1-shot 90.4 -> 90.0No clear effect
pre-train on TOP(+TOPv2) only vs no pre-training (ablation)L-PIE · 4 IC datasets, N-wayaccuracy: 68.3 -> 73.1 (0-shot); 78.0 -> 81.7 (1-shot)Improved
add DSTC11-T2 and SGD to TOP pre-training data (ablation)L-PIE · 4 IC datasets, N-way 0-shot averageaccuracy: 73.1 -> 73.7Improved
remove overlapping intents from evaluation set (ablation)L-PIE · Banking77 / HWU64 / Clinc150, N-way 0-shotaccuracy: Banking77 71.4 -> 72.0; HWU64 68.7 -> 69.6; Clinc150 83.1 -> 82.8Mixed
increase number of candidate intents NPIE vs baselines · N-way 0-shotaccuracyImproved