AI Paper Atlas

Research map / Video / Video segmentation and tracking

Towards Noise-Tolerant Speech-Referring Video Object Segmentation: Bridging Speech and Text

Xiang Li, Jinglu Wang, Xiaohao Xu, Muqiao Yang, Fan Yang, Yizhou Zhao, Rita Singh, Bhiksha Raj

EMNLP 2023Video › Video segmentation and trackingapproach: Matching-based video object segmentation19 citations (OpenAlex)

Carnegie Mellon University · Microsoft · University of Michigan - Ann Arbor · The Ohio State University · Mohamed bin Zayed University of Artificial Intelligence

Read the paperPlace an idea next to itCheck your own paper ↗

13measured effects
8improved
2no clear effect
3hurt

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use STBridge on speech instead of ASR-converted textReferFormer · AVOS test, clean speechJ&F: 58.4 -> 65.5Improved
use STBridge on speech instead of ASR-converted textReferFormer · AVOS test, 10 dB noiseJ: 50.3 -> 59.9Improved
replace text query with ASR-converted textReferFormer · AVOS test, clean speechJ&F: 67.2 -> 58.4Hurt
add SJS module to semantic alignment (ablation)STBridge · AVOS test, noisy speechJ&F: 55.7 -> 59.7Improved
add SJS module to semantic alignment (ablation)STBridge · AVOS test, clean speechJ&F: 61.0 -> 61.3No clear effect
add NSA module to semantic alignment (ablation)STBridge · AVOS test, noisy speechJ&F: 55.7 -> 61.4Improved
add NSA and SJS to semantic alignment (ablation)STBridge · AVOS test, noisy speechJ&F: 55.7 -> 62.4Improved
add random noise to word and channel masking jitter (ablation)STBridge · AVOS test, noisy speech (10 dB)J&F: 61.9 -> 62.4Improved
update R-VOS parameters during training (ablation)STBridge · AVOS testJ&F: 65.5 -> 58.9Hurt
use L2 loss instead of cosine loss for alignment (ablation)STBridge · AVOS test, noisy speechJ&F: 60.9 -> 62.4Improved
use masking ratio 0.1 instead of 0.2 (ablation)STBridge · AVOS test, noisy speechJ&F: 60.3 -> 62.4Improved
vary training window size (1,3,5,7) (ablation)STBridge · AVOS test, noisy speechJ&F: 59.4 / 61.7 / 62.4 / 62.3No clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy