AI Paper Atlas

Research map / Vision-language and multimodal / Human and embodied modeling

BioT5: Enriching Cross-modal Integration in Biology with Chemical Knowledge and Natural Language Associations

Qizhi Pei, Wei Zhang, Jinhua Zhu, Kehan Wu, Kaiyuan Gao, Lijun Wu, Yingce Xia, Rui Yan

EMNLP 2023Vision-language and multimodal › Human and embodied modelingapproach: Medical vision-language models191 citations (OpenAlex)

Microsoft · Renmin University of China · Beijing Key Laboratory of Big Data Management and Analysis Methods · Huazhong University of Science and Technology · University of Science and Technology of China

Read the paperPlace an idea next to itCheck your own paper ↗

11measured effects
8improved
1no clear effect
2hurt

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use BioT5 instead of MolXPTBioT5 · MoleculeNet averageAUROC: 81.9 -> 82.4Improved
use BioT5 instead of ESM-1bBioT5 · PEER solubilityaccuracy: 70.23 -> 74.65Improved
use BioT5 instead of ESM-1bBioT5 · PEER localizationaccuracy: 92.40 -> 91.69Hurt
use BioT5 instead of DrugBANBioT5 · BioSNAP DTIAUROC: 0.903 -> 0.937Improved
use BioT5 instead of DrugBANBioT5 · Human DTIAUROC: 0.982 -> 0.989Improved
use BioT5 instead of ESM-1b (head tuned only)BioT5 · Yeast PPIaccuracy: 66.07 -> 64.89Hurt
use BioT5 instead of fully fine-tuned ESM-1bBioT5 · Yeast PPIaccuracy: 57.00 -> 64.89Improved
use BioT5 instead of MolT5-largeBioT5 · ChEBI-20 captioningBLEU-4: 0.508 -> 0.556Improved
use BioT5 instead of MolT5-largeBioT5 · ChEBI-20 molecule generationExact match: 0.311 -> 0.413Improved
use BioT5 with SELFIES instead of MolXPTBioT5 · ChEBI-20 molecule generationValidity: 0.983 -> 1.000Improved
use BioT5 instead of MolXPTBioT5 · ChEBI-20 molecule generationText2Mol: 0.578 vs 0.576No clear effect

Later papers that compared with this method

1 later accepted paper reports BioT5+ as a baseline in their results tables; 1 of them report a better number on most of the results they share with it.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy