AI Paper Atlas

Research map / Large language models / Language, safety and interpretability

Symbol tuning improves in-context learning in language models

Jerry Wei, Le Hou, Andrew Lampinen, Xiangning Chen, Da Huang, Yi Tay, Xinyun Chen, Yifeng Lu, Denny Zhou, Tengyu Ma, Quoc V. Le

EMNLP 2023Large language models › Language, safety and interpretabilityapproach: In-context learning analysis129 citations (OpenAlex)

Stanford University · Google

Read the paperPlace an idea next to itCheck your own paper ↗

15measured effects
8improved
3no clear effect
4hurt

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add symbol tuningFlan-PaLM-62B · ICL avg, no relevant labels, no instructionsaccuracy (%): 50.5 -> 60.3Improved
add symbol tuningFlan-PaLM-540B · ICL avg, no relevant labels, no instructionsaccuracy (%): 58.1 -> 63.6Improved
add symbol tuningFlan-PaLM-8B · ICL avg, relevant labels and instructionsaccuracy (%): 63.9 -> 57.6Hurt
add symbol tuningFlan-PaLM-62B and larger · ICL avg, relevant labels availableaccuracy (%): +0.8% to +4.2%Improved
add symbol tuningFlan-PaLM models · List Functionsaccuracy (%): +18.2% (8B), +11.1% (62B), +3.6% (540B)Improved
add symbol tuningFlan-PaLM models · Simple Turing Conceptsaccuracy (%): +15.3% (8B, 62B), +4.7% (540B)Improved
add symbol tuningFlan-PaLM models · flipped-label ICLaccuracy (%): +26.5% (8B), +33.7% (62B), +34.0% (540B)Improved
continue instruction tuning instead of symbol tuning (ablation)Flan-PaLM-540B · flipped labelsaccuracy (%): 19.2 vs 54.7 with symbol tuningNo clear effect
symbol-tune with only one or two datasets instead of many (ablation)Flan-PaLM models · ICL settings with relevant labelsaccuracy (%)Hurt
use more datasets for symbol tuning (ablation)Flan-PaLM-8B and 62B · ICL avg of 11 tasksaccuracy (%)Improved
increase symbol-tuning step count beyond 1k-2k (ablation)Flan-PaLM-8B and 62B · ICL avg of 11 tasksaccuracy (%)No clear effect
tune Flan-PaLM-540B beyond 1k steps (ablation)Flan-PaLM-540B · ICL avg of 11 tasksaccuracy (%)Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy