Research map / Large language models / Alignment and preferences
Model Merging and Safety Alignment: One Bad Model Spoils the Bunch
Hasan Abed Al Kader Hammoud, Umberto Michieli, Fabio Pizzati, Philip Torr, Adel Bibi, Bernard Ghanem, Mete Ozay
Samsung · University of Oxford · KAUST
Read the paperPlace an idea next to itCheck your own paper ↗
14measured effects
6improved
3no clear effect
4hurt
1mixed
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add generated safety data D_safety to the EvoMM objective (ablation) | TIES + EvoMM · BeaverTails30K alignment (BIO merge) | safe response rate (%): 79.8 -> 96.0 | Improved |
| add generated safety data D_safety to the EvoMM objective (ablation) | TIES + EvoMM · BeaverTails30K alignment (STEM merge) | safe response rate (%): 61.6 -> 78.1 | Improved |
| add D_safety to the EvoMM objective (ablation) | TIES + EvoMM · STEM accuracy | accuracy: 52.0 -> 54.2 | Improved |
| add D_safety to the EvoMM objective (ablation) | TIES + EvoMM · BIO accuracy | accuracy: 73.2 -> 73.6 | No clear effect |
| add D_safety to LM-Cocktail (ablation) | LM-Cocktail · BeaverTails30K alignment (BIO / STEM) | safe response rate (%): +1.9 (72.5 -> 74.4 STEM), +1.5 (92.6 -> 94.1 BIO) | Improved |
| add D_safety to LM-Cocktail (ablation) | LM-Cocktail · STEM / BIO accuracy | accuracy: 53.3 -> 53.2; 74.1 -> 74.0 | No clear effect |
| use EvoMM with D_expert only instead of grid search | TIES · BeaverTails30K alignment (STEM merge) | safe response rate (%): 72.7 -> 61.6 | Hurt |
| add D_safety in three-model merge (ablation) | TIES + EvoMM · BeaverTails30K alignment (3-model merge) | safe response rate (%): 49.1 -> 76.6 | Improved |
| raise loss weight alpha from 0.3 to 1 (ablation) | TIES + EvoMM (ours) · BeaverTails30K alignment (BIO merge) | safe response rate (%): 96.0 -> 88.9 | Hurt |
| replace generated data with real data (ablation) | TIES + EvoMM (ours) · BIO merge | alignment and accuracy: +0.2 alignment, +0.2 accuracy (96.0 -> 96.2; 73.6 -> 73.8) | No clear effect |
| replace generated data with real data (ablation) | TIES + EvoMM (D_expert only) · BeaverTails30K alignment (BIO merge) | safe response rate (%): 79.8 -> 89.7 | Improved |
| vary number of samples K (200, 500, 1000) (ablation) | TIES + EvoMM (ours) · BIO merge | alignment: 95.6 (K=200), 93.0 (K=500), 96.0 (K=1000) | Mixed |
Closest papers by meaning
- MergeBench: A Benchmark for Merging Domain-Specialized LLMs (NeurIPS 2025 · similarity 0.90)
- Mix Data or Merge Models? Balancing the Helpfulness, Honesty, and Harmlessness of Large Language Model via Model Merging (NeurIPS 2025 · similarity 0.90)
- Gaining Wisdom from Setbacks: Aligning Large Language Models via Mistake Analysis (ICLR 2024 · similarity 0.90)
- Navigating the Safety Landscape: Measuring Risks in Finetuning Large Language Models (NeurIPS 2024 · similarity 0.89)
- Fine-tuning Aligned Language Models Compromises Safety, Even When Users Do Not Intend To! (ICLR 2024 · similarity 0.89)
- Principled Data Selection for Alignment: The Hidden Risks of Difficult Examples (ICML 2025 · similarity 0.88)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
