AI Paper Atlas

Research map / Large language models / Language, safety and interpretability

Lost in Translation: Chemical Language Models and the Misunderstanding of Molecule Structures

Veronika Ganeeva, Andrey Sakhovskiy, Kuzma Khrabrov, Andrey Savchenko, Artur Kadurin, Elena Tutubalina

EMNLP 2024Large language models › Language, safety and interpretabilityapproach: Controlled text generation12 citations (OpenAlex)

AIRI · Sber AI · Skoltech · HSE University · ISP RAS Research Center for Trusted Artificial Intelligence · Sber AI Lab

Read the paperPlace an idea next to itCheck your own paper ↗

11measured effects
2improved
2no clear effect
6hurt
1mixed

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add explicit hydrogens to SMILES input (ablation)Text+Chem T5-standard · ChEBI-20 retrievalAcc@1: 63.03 (canon) -> 5.46 (hydro)Hurt
add explicit hydrogens to SMILES input (ablation)all ChemLMs · Isomers retrievalAcc@1: all models below 1% Acc@1Hurt
use a graph neural network instead of a SMILES language modelGNN vs ChemLMs · ChEBI-20 retrievalAcc@1: e.g. 92.42 vs 32.79 (canon, PubChemDeBERTa)Improved
use cross-modal (text+chemistry) pre-training instead of unimodalMolT5 / Text+Chem T5 · ChEBI-20 retrieval (canon, hydro, kekul)Acc@1: e.g. 63.03 (Text+Chem T5-standard) vs 23.85 (ZINC-GPT) canonImproved
cycle renumbering augmentation for cross-modal vs otherscross-modal models · ChEBI-20 retrieval (cycles)Acc@1: SciFive 98.48 vs Text+Chem T5-standard 96.7Mixed
augment SMILES in MoleculeNet test sets with hydrogen (ablation)PubChemDeBERTa · MoleculeNet BACEaccuracy: 0.8 -> 0.38Hurt
use hydrogen augmentation on ESOL regression (ablation)chemical LMs · MoleculeNet ESOLRMSE: 0.87 -> 7.93Hurt
use cycle renumbering augmentation on ESOL (ablation)Text+Chem T5-standard · MoleculeNet ESOLRMSE: 0.93 -> 0.99Hurt
pre-train Text+Chem T5 with augmented data (augm) vs standard (ablation)Text+Chem T5 · ChEBI-20 retrievalAcc@1: canon 63.03 -> 60.64; kekul 76.76 -> 77.09No clear effect
hydrogen augmentation in captioning (ablation)Text+Chem T5-standard · ChEBI-20 captioningROUGE-2: 0.381 (canon) -> 0.187 (hydro)Hurt
use any intermediate layer instead of last layer (ablation)T5 ChemLMs · ChEBI-20 retrievalAcc@1No clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy