Research map / Large language models / Instruction and fine-tuning
MedINST: Meta Dataset of Biomedical Instructions
Wenhan Han, Meng Fang, Zihan Zhang, Yu Yin, Zirui Song, Ling Chen, Mykola Pechenizkiy, Qingyu Chen
University of Liverpool · University of Technology Sydney · Yale University · Eindhoven University of Technology
Read the paperPlace an idea next to itCheck your own paper ↗
10measured effects
3improved
3no clear effect
3hurt
1mixed
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| instruction fine-tune on MI32 (MedINST subset) | LLaMA3 (8B) · MedINST32 NCBI-disease | Label-F1: 51.67 -> 78.55 | Improved |
| instruction fine-tune on MI32 (MedINST subset) | LLaMA3 (8B) · MedINST32 BC5CDR-RE | Entity-F1: 4.28 -> 14.21 | Improved |
| instruction fine-tune on MI32 (MedINST subset) | LLaMA3 (8B) · MedINST32 MedQA | EM: 49.25 -> 47.68 | No clear effect |
| use MMed-LLaMA-3 (biomedical further pretraining) instead of LLaMA-3 as base for MI32 tuning | MI32 fine-tuning · MedINST32 | task scores: MMedL3-MI32 lagged LLaMA3-MI32 in 22 tasks | Hurt |
| fine-tune on English medical instruction data of a single QA format (MMedL3-EnIns) | MMed-LLaMA-3 · MedINST32 MedQA | EM: 15.40 (vs LLaMA3 49.25) | Hurt |
| increase MI32 training samples (5K, 50K, 100K) (ablation) | MMedL3-MI32 · MedINST32 | average Rouge-L per category | Mixed |
| scale Phi-3 from 4B to 14B (50K samples) (ablation) | Phi-3 · MedINST32 NER/RE/EE | average Rouge-L | Hurt |
| oracle: include MedINST32 datasets' training sets (LLaMA3-MI) | LLaMA3-MI32 · MedINST32 NCBI-disease | Label-F1: 78.55 -> 84.61 | Improved |
| instruction fine-tune on MedINST (LLaMA3-MI) and test on public MMLU medical subtasks | LLaMA3 · MMLU medical subtasks | average accuracy: 73.92 -> 74.38 | No clear effect |
| instruction fine-tune MMed-LLaMA-3 on MedINST 100K (MMedL3-MI) and test on MMLU | MMedL3 · MMLU medical subtasks | average accuracy: 67.03 -> 66.76 | No clear effect |
Closest papers by meaning
- MedMax: Mixed-Modal Instruction Tuning for Training Biomedical Assistants (NeurIPS 2025 · similarity 0.87)
- Biomedical Visual Instruction Tuning with Clinician Preference Alignment (NeurIPS 2024 · similarity 0.86)
- MedAlign: A Clinician-Generated Dataset for Instruction Following with Electronic Medical Records (AAAI 2024 · similarity 0.86)
- Uni-Med: A Unified Medical Generalist Foundation Model For Multi-Task Learning Via Connector-MoE (NeurIPS 2024 · similarity 0.85)
- MedBench: A Large-Scale Chinese Benchmark for Evaluating Medical Large Language Models (AAAI 2024 · similarity 0.85)
- Instruction Tuning Large Language Models to Understand Electronic Health Records (NeurIPS 2024 · similarity 0.84)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
