Research map / Large language models / Instruction and fine-tuning
MedAdapter: Efficient Test-Time Adaptation of Large Language Models Towards Medical Reasoning
Wenqi Shi, Ran Xu, Yuchen Zhuang, Yue Yu, Haotian Sun, Hang Wu, Carl Yang, May D. Wang
Emory University · Georgia Tech
Read the paperPlace an idea next to itCheck your own paper ↗
14measured effects
8improved
2no clear effect
4hurt
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
On benchmark leaderboards
- MedQA leaderboard accuracy 68.66 · rank 41 of 71 papers
- PubMedQA leaderboard accuracy 58 · rank 32 of 35 papers
- MedMCQA leaderboard accuracy 65.5 · rank 10 of 30 papers
- BioASQ leaderboard accuracy 95.97 · rank 3 of 10 papers
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add MedAdapter test-time adapter | LLaMA-2-7B · BioASQ | accuracy (%): 16.13 -> 62.90 | Improved |
| add MedAdapter instead of supervised fine-tuning | LLaMA-2-7B · BioASQ | accuracy (%) and GPU memory: SFT 63.31 vs MedAdapter 62.90; training memory 78.65 vs 11.60 GiB | No clear effect |
| add MedAdapter instead of LoRA fine-tuning | LLaMA-2-7B · BioASQ | accuracy (%): 50.00 -> 62.90 | Improved |
| add MedAdapter instead of self-consistency | gpt-3.5-turbo · MedMCQA | accuracy (%): 56.20 -> 59.02 | Improved |
| add MedAdapter instead of Azure fine-tuning API | gpt-3.5-turbo · MedQA | accuracy (%): 63.32 -> 68.66 | Improved |
| add MedAdapter instead of Azure fine-tuning API | gpt-3.5-turbo · MedMCQA | accuracy (%): 61.82 -> 59.02 | Hurt |
| add MedRAG | gpt-3.5-turbo · PubMedQA | accuracy (%): 56.00 -> 50.00 | Hurt |
| add MedAdapter on top of supervised fine-tuning | LLaMA-2-7B · MedMCQA | accuracy (%): 42.86 -> 44.85 | Improved |
| add MedAdapter on top of Azure-SFT | gpt-3.5-turbo · BioASQ | accuracy (%): 95.16 -> 95.97 | Improved |
| replace cross-entropy with InfoNCE loss (ablation) | MedAdapter · BioASQ | accuracy (%): 93.55 -> 87.90 | Hurt |
| replace cross-entropy with pairwise loss (ablation) | MedAdapter · BioASQ | accuracy (%): 93.55 -> 92.74 | Hurt |
| scale adapter base model from 110M to 2.7B parameters (ablation) | MedAdapter · biomedical QA | accuracy | No clear effect |
Closest papers by meaning
- Medical Adaptation of Large Language and Vision-Language Models: Are We Making Progress? (EMNLP 2024 · similarity 0.89)
- Medmarks: A Comprehensive Open-Source LLM Benchmark Suite for Medical Tasks (NeurIPS 2026 · similarity 0.87)
- CGBench: Benchmarking Language Model Scientific Reasoning for Clinical Genetics Research (NeurIPS 2025 · similarity 0.85)
- MedMax: Mixed-Modal Instruction Tuning for Training Biomedical Assistants (NeurIPS 2025 · similarity 0.85)
- Instruction Tuning Large Language Models to Understand Electronic Health Records (NeurIPS 2024 · similarity 0.85)
- Enhancing Small Medical Learners with Privacy-preserving Contextual Prompting (ICLR 2024 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
