AI Paper Atlas

Research map / 3D vision / Depth and stereo

Polarimetric Camera Calibration Using an LCD Monitor

Zhixiang Wang, Yinqiang Zheng, Yung-Yu Chuang

CVPR 2019 · 3D vision › Depth and stereo · approach: Spike and event camera reconstruction · 8 citations (OpenAlex)

Check your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use LCD-based joint ICRF and polarizer-angle calibration instead of Teo's self-calibrationPolarimetric camera calibration · Real-world bright roomAng. err.: 12.56±7.31 -> 0.63±0.18Improved
Use LCD-based joint ICRF and polarizer-angle calibration instead of Schechner's method with ICRFPolarimetric camera calibration · Real-world bright roomAng. err.: 15.84±29.59 -> 0.63±0.18Improved
Use joint ICRF and polarizer-angle refinement rather than separate calibration (ablation)Polarimetric camera calibration · Real-worldAng. err.: 0.83 -> 0.48Improved
Use joint ICRF and polarizer-angle refinement rather than separate calibration (ablation)Polarimetric camera calibration · Real-worldCRF err.: 0.02 -> 0.01Improved
Use adapted checker pattern P3 instead of P1 (ablation)Joint calibration · Real-worldAng. err.: 1.24±0.43 -> 0.48±0.15Improved
Use adapted checker pattern P3 instead of P1 (ablation)Joint calibration · Real-worldCRF err.: 0.07±0.02 -> 0.01±0.01Improved
Use pattern P2 instead of P3 (ablation)Joint calibration · Real-worldAng. err.: 0.48±0.15 -> 0.38±0.32Mixed
Use pattern P2 instead of P3 (ablation)Joint calibration · Real-worldCRF err.: 0.01±0.01 -> 0.02±0.02Hurt
Estimate ICRF jointly rather than assuming a known ICRF (ablation)Proposed polarizer-angle calibration · Real-world bright roomAng. err.: 0.62±0.28 -> 0.63±0.18Improved
Increase the number of polarizer angles from 4 to 18 (ablation)Proposed method · Synthetic, unknown ICRFAngular RMSE: 0.09 degrees; 0.18 degreesMixed
Subtract monitor-off images to remove environmental illumination (ablation)Proposed method · Real-world bright roomAng. err.: 0.05±0.01Improved
Use the proposed method rather than Schechner's method as the number of polarizer angles decreasesPolarizer-angle calibration · Real-world, varying number of polarizer anglesAngular RMSEImproved