atlas

Research map / Vision-language and multimodal / Human and embodied modeling

Interpretable and Fine-Grained Visual Explanations for Convolutional Neural Networks

CVPR 2019 · Vision-language and multimodal › Human and embodied modeling · approach: Abstract visual reasoning benchmarks · 147 citations (OpenAlex)

Check your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's title only (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use FGVis instead of Sliding Window for pixel importanceResNet50 · ImageNet validationdeletion metric: 0.1421 -> 0.0644Helped
Use FGVis instead of Sliding Window for pixel importanceVGG16 · ImageNet validationdeletion metric: 0.1158 -> 0.0636Helped
Apply neuron-activation gradient filtering during explanation optimizationFGVis · ImageNet validation images, VGG16adversarial class generated (%): 100.0\,\% -> 0.2\,\%Helped
Apply neuron-activation gradient filtering during explanation optimizationFGVis · ImageNet validation images, AlexNetadversarial class generated (%): 100.0\,\% -> 0.0\,\%Helped
Apply neuron-activation gradient filtering during explanation optimizationFGVis · ImageNet validation images, ResNet50adversarial class generated (%): 100.0\,\% -> 0.0\,\%Helped
Apply neuron-activation gradient filtering during explanation optimizationFGVis · ImageNet validation images, GoogleNetadversarial class generated (%): 100.0\,\% -> 0.0\,\%Helped
Use 50% rather than 25% overlap to count a lesion as detected (ablation)FGVis · DiaretDB1, hemorrhagesimage-level sensitivity (%): 100 -> 90.5Hurt
Use 50% rather than 25% overlap to count a lesion as detected (ablation)FGVis · DiaretDB1, hard exudatesimage-level sensitivity (%): 94.7 -> 81.6Hurt
Use 50% rather than 25% overlap to count a lesion as detected (ablation)FGVis · DiaretDB1, soft exudatesimage-level sensitivity (%): 90.0 -> 80.0Hurt
Use 50% rather than 25% overlap to count a lesion as detected (ablation)FGVis · DiaretDB1, red small dotsimage-level sensitivity (%): 88.4 -> 86.0Hurt
Use a zero reference image instead of Gaussian noise or blurred-image references (ablation)FGVis · ImageNet reference-image entropyentropy: Zero image: AlexNet 6.90, GoogleNet 4.08, VGG16 6.31, ResNet50 5.09Mixed

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy