AI Paper Atlas

Research map / Vision-language and multimodal / Visual question answering

BioPIE: A Biomedical Protocol Information Extraction Dataset for Experiment Understanding

Haofei Hou, Shunyi Zhao, Fanxu Meng, Kairui Yang, Lecheng Ruan, Qining Wang

EMNLP 2026Vision-language and multimodal › Visual question answeringapproach: Open-domain multimodal QA0 citations (OpenAlex)

Peking University

Read the paperPlace an idea next to itCheck your own paper ↗

14measured effects
9improved
3no clear effect
2hurt

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add BioPIE knowledge-graph input to sentences (ablation)KG-augmented QA · BioPIE QA testaccuracy (%): 55.69 -> 72.99Improved
add sentence retrieval alongside the graph (ablation)KG-augmented QA · BioPIE QA testaccuracy (%): 59.84 -> 72.99Improved
add reasoning planner (ablation)KG-augmented QA · BioPIE QA MSRaccuracy (%): 62.60 -> 74.80 (test 72.29 -> 72.99)Improved
build KG with IE model trained on BioPIE instead of SciERC (ablation)KG-augmented QA · BioPIE QA testaccuracy (%): 62.40 -> 72.99Improved
build KG with IE model trained on BioPIE instead of ChemProt (ablation)KG-augmented QA · BioPIE QA testaccuracy (%): 64.70 -> 72.99Improved
add retrieval (BM25) to a frozen LLMLlama-3-8B · BioPIE QA testaccuracy (%): 14.74 -> 63.72Improved
LoRA fine-tune the LLM on QA training data without retrievalLlama-3-8B · BioPIE QA testaccuracy (%): 14.74 -> 12.44Hurt
provide few-shot demonstrationsGPT-5, Claude-4.5-Opus, Qwen-max (pipeline) · BioPIE IE in-domainRel+ F1: GPT-5 41.14 -> 59.73; Claude 31.90 -> 63.47Improved
use pipeline instead of joint extractionLLMs (zero-shot) · BioPIE IE in-domainRel+ F1: GPT-5 17.54 -> 41.14Improved
replace SciBERT with BioBERT encoder (ablation)PL-Marker · BioPIE IE out-of-domainRel F1: 70.27 -> 23.51Hurt
replace SciBERT with BioBERT encoder (ablation)HGERE · BioPIE IE out-of-domainRel F1: 70.49 -> 69.48No clear effect
increase number of few-shot demonstrations beyond about 5-15few-shot LLMs · BioPIE IERel+ F1No clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy