Research map / Vision-language and multimodal / Visual question answering
BioPIE: A Biomedical Protocol Information Extraction Dataset for Experiment Understanding
Haofei Hou, Shunyi Zhao, Fanxu Meng, Kairui Yang, Lecheng Ruan, Qining Wang
Peking University
Read the paperPlace an idea next to itCheck your own paper ↗
14measured effects
9improved
3no clear effect
2hurt
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add BioPIE knowledge-graph input to sentences (ablation) | KG-augmented QA · BioPIE QA test | accuracy (%): 55.69 -> 72.99 | Improved |
| add sentence retrieval alongside the graph (ablation) | KG-augmented QA · BioPIE QA test | accuracy (%): 59.84 -> 72.99 | Improved |
| add reasoning planner (ablation) | KG-augmented QA · BioPIE QA MSR | accuracy (%): 62.60 -> 74.80 (test 72.29 -> 72.99) | Improved |
| build KG with IE model trained on BioPIE instead of SciERC (ablation) | KG-augmented QA · BioPIE QA test | accuracy (%): 62.40 -> 72.99 | Improved |
| build KG with IE model trained on BioPIE instead of ChemProt (ablation) | KG-augmented QA · BioPIE QA test | accuracy (%): 64.70 -> 72.99 | Improved |
| add retrieval (BM25) to a frozen LLM | Llama-3-8B · BioPIE QA test | accuracy (%): 14.74 -> 63.72 | Improved |
| LoRA fine-tune the LLM on QA training data without retrieval | Llama-3-8B · BioPIE QA test | accuracy (%): 14.74 -> 12.44 | Hurt |
| provide few-shot demonstrations | GPT-5, Claude-4.5-Opus, Qwen-max (pipeline) · BioPIE IE in-domain | Rel+ F1: GPT-5 41.14 -> 59.73; Claude 31.90 -> 63.47 | Improved |
| use pipeline instead of joint extraction | LLMs (zero-shot) · BioPIE IE in-domain | Rel+ F1: GPT-5 17.54 -> 41.14 | Improved |
| replace SciBERT with BioBERT encoder (ablation) | PL-Marker · BioPIE IE out-of-domain | Rel F1: 70.27 -> 23.51 | Hurt |
| replace SciBERT with BioBERT encoder (ablation) | HGERE · BioPIE IE out-of-domain | Rel F1: 70.49 -> 69.48 | No clear effect |
| increase number of few-shot demonstrations beyond about 5-15 | few-shot LLMs · BioPIE IE | Rel+ F1 | No clear effect |
Closest papers by meaning
- BioBridge: Bridging Biomedical Foundation Models via Knowledge Graphs (ICLR 2024 · similarity 0.86)
- Benchmarking the Scientific Mind: A Pathology-Derived Biomedical VQA Benchmark for Complex Scientific Reasoning (ICML 2026 · similarity 0.86)
- BioPlanner: Automatic Evaluation of LLMs on Protocol Planning in Biology (EMNLP 2023 · similarity 0.86)
- Unleashing Scientific Reasoning for Bio-experimental Protocol Generation via Structured Component-based Reward Mechanism (ICLR 2026 · similarity 0.86)
- Can Language Models be Biomedical Knowledge Bases? (EMNLP 2021 · similarity 0.85)
- MicroVQA: A Multimodal Reasoning Benchmark for Microscopy-Based Scientific Research (CVPR 2025 · similarity 0.84)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
