Research map / Large language models / Instruction and fine-tuning
Contextualized Divergence Detection in Health Advice: A Benchmark and Analysis
Reet Kothari, Sirajum Munir, Madhusudan Basak, Sarah Preum
Dartmouth College · Bosch Research · University of Massachusetts Amherst
Read the paperPlace an idea next to itCheck your own paper ↗
10measured effects
5improved
1no clear effect
3hurt
1mixed
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add top-5 retrieval of profile-linked medication documents | o3-mini · Divergence benchmark, 3x500 balanced subsets | binary F1: 0.75 -> 0.85 | Improved |
| add top-5 retrieval of profile-linked medication documents | o3-mini · Divergence benchmark, 3x500 balanced subsets | multi-class macro F1: 0.68 -> 0.70 | Improved |
| add RAG | Qwen3-1.7B / Qwen3-8B / MedGemma-4B · Divergence benchmark, full 2,110 test set | multi-class macro F1: Qwen3-8B 0.26 -> 0.20; MedGemma-4B 0.18 -> 0.26 | No clear effect |
| add LoRA supervised fine-tuning | Qwen3-8B · Divergence benchmark, full 2,110 test set | binary F1: 0.57 -> 0.88 | Improved |
| add LoRA supervised fine-tuning | Qwen3-8B · Divergence benchmark, full 2,110 test set | multi-class macro F1: 0.26 -> 0.33 | Improved |
| add LoRA fine-tuning | small models · Divergence benchmark, full 2,110 test set | binary recall: MedGemma-4B 0.18 -> 0.73; Qwen3-8B 0.42 -> 0.94 | Improved |
| replace zero-shot with chain-of-thought prompting | Mixtral 8x7B and Llama-3.3-70B · Divergence benchmark, 3x500 balanced subsets | binary recall / precision: Mixtral CoT recall 0.96, precision 0.52; Llama CoT recall 0.95, precision 0.51 | Mixed |
| use multi-agent debate instead of RAG | o3-mini · Divergence benchmark, 3x500 balanced subsets | binary F1: 0.85 -> 0.70 | Hurt |
| remove medication documents (No Documents) (ablation) | contextual grounding ablation · Contextual grounding ablation | per-class F1 (temporal, sub-typical): temporal 0.000; sub-typical 0.000 | Hurt |
| use a biomedical encoder instead of text-embedding-3-large for retrieval (ablation) | RAG retriever · retrieval accuracy | top-k retrieval accuracy: 87.4% at k=3 (OpenAI) vs below 33% (BioBERT) | Hurt |
Closest papers by meaning
- Assessing and Mitigating Medical Knowledge Drift and Conflicts in Large Language Models (EMNLP 2025 · similarity 0.87)
- ``What's Up, Doc?'': Analyzing How Users Seek Health Information in Large-Scale Conversational AI Datasets (EMNLP 2025 · similarity 0.86)
- Can Large Language Models Match the Conclusions of Systematic Reviews? (ICLR 2026 · similarity 0.86)
- A Comprehensive Survey on the Trustworthiness of Large Language Models in Healthcare (EMNLP 2025 · similarity 0.85)
- TherapyGym: Evaluating and Aligning Clinical Fidelity and Safety in Therapy Chatbots (NeurIPS 2026 · similarity 0.85)
- Can LLMs Take Retrieved Information with a Grain of Salt? (NeurIPS 2026 · similarity 0.84)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.