AI Paper Atlas

Research map / Large language models / Instruction and fine-tuning

Contextualized Divergence Detection in Health Advice: A Benchmark and Analysis

Reet Kothari, Sirajum Munir, Madhusudan Basak, Sarah Preum

EMNLP 2026Large language models › Instruction and fine-tuningapproach: Fine-tuning generalization and delta compression0 citations (OpenAlex)

Dartmouth College · Bosch Research · University of Massachusetts Amherst

Read the paperPlace an idea next to itCheck your own paper ↗

10measured effects
5improved
1no clear effect
3hurt
1mixed

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add top-5 retrieval of profile-linked medication documentso3-mini · Divergence benchmark, 3x500 balanced subsetsbinary F1: 0.75 -> 0.85Improved
add top-5 retrieval of profile-linked medication documentso3-mini · Divergence benchmark, 3x500 balanced subsetsmulti-class macro F1: 0.68 -> 0.70Improved
add RAGQwen3-1.7B / Qwen3-8B / MedGemma-4B · Divergence benchmark, full 2,110 test setmulti-class macro F1: Qwen3-8B 0.26 -> 0.20; MedGemma-4B 0.18 -> 0.26No clear effect
add LoRA supervised fine-tuningQwen3-8B · Divergence benchmark, full 2,110 test setbinary F1: 0.57 -> 0.88Improved
add LoRA supervised fine-tuningQwen3-8B · Divergence benchmark, full 2,110 test setmulti-class macro F1: 0.26 -> 0.33Improved
add LoRA fine-tuningsmall models · Divergence benchmark, full 2,110 test setbinary recall: MedGemma-4B 0.18 -> 0.73; Qwen3-8B 0.42 -> 0.94Improved
replace zero-shot with chain-of-thought promptingMixtral 8x7B and Llama-3.3-70B · Divergence benchmark, 3x500 balanced subsetsbinary recall / precision: Mixtral CoT recall 0.96, precision 0.52; Llama CoT recall 0.95, precision 0.51Mixed
use multi-agent debate instead of RAGo3-mini · Divergence benchmark, 3x500 balanced subsetsbinary F1: 0.85 -> 0.70Hurt
remove medication documents (No Documents) (ablation)contextual grounding ablation · Contextual grounding ablationper-class F1 (temporal, sub-typical): temporal 0.000; sub-typical 0.000Hurt
use a biomedical encoder instead of text-embedding-3-large for retrieval (ablation)RAG retriever · retrieval accuracytop-k retrieval accuracy: 87.4% at k=3 (OpenAI) vs below 33% (BioBERT)Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy