AI Paper Atlas

Research map / Large language models / Retrieval and knowledge

ToToFilter: Topic- and Topology-Aware Noise Filtering Framework over Medical KGs for Evidence-Based Medical Q&A

Yufeng Wang, Weijie Chen, Chao Chen, Xingfeng Liu, Yizhe Yang, Zhihao Chen, Qiming He, Yubo Chen, Kang Liu, Xuefeng Wang, Xiangwen Liao, Jingfeng Liu

EMNLP 2026Large language models › Retrieval and knowledgeapproach: Domain-specific QA datasets0 citations (OpenAlex)

Fuzhou University · Fujian Medical University · Harbin Institute of Technology · Fujian Jiangxia University · Minzu University of China · Chinese Academy of Sciences

Read the paperPlace an idea next to itCheck your own paper ↗

12measured effects
7improved
2no clear effect
3hurt

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

On benchmark leaderboards

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use ToToFilter instead of DALKLlama3.1-8B · four MQA benchmarks (avg)accuracy (%): 73.58 -> 75.88Improved
Use ToToFilter instead of DALKQwen2.5-7B · MedQAaccuracy (%): 60.30 -> 63.08Improved
Use ToToFilter instead of DALK (other seven backbone-dataset comparisons)ToToFilter · paired testssignificance: confidence intervals include zeroNo clear effect
Add unfiltered direct KG retrieval (BasicKG, GoG) to Llama3.1-8BLlama3.1-8B · MedQAaccuracy (%): 60.21 -> 49.33 (BasicKG)Hurt
Use ToToFilter instead of second-best methodLlama3.1-8B · PrimeKGQAanswer / triple recall: +8.81 answer recall, +19.70 triple recallImproved
Add TEL (topic-aware entity localization) (ablation)ToToFilter · MedQAaccuracy (%): Llama3.1-8B 67.01 -> 68.03; Qwen2.5-7B 61.43 -> 63.08Improved
Add TPF (topology-aware path filtering) (ablation)ToToFilter · MedQAaccuracy (%): Llama3.1-8B 67.24 -> 68.03; Qwen2.5-7B 61.35 -> 63.08Improved
Add all three TPF scoring terms (Sem, Len, Deg) (ablation)TPF · MedQA (Qwen2.5-7B)accuracy (%): 61.35 -> 63.08Improved
Add Len or Deg term alone (ablation)TPF · MedQA (Qwen2.5-7B)accuracy (%): 61.35 -> 61.32 (Len), 61.43 (Deg)No clear effect
Use full TPF scoring (ablation)TPF · MedQA (Qwen2.5-7B)average degree: 2380.39 -> 1058.64Improved
Remove answer options from retrieval (ablation)ToToFilter · macro-average accuracyaccuracy (pp): -1.50 (Llama3.1-8B), -0.84 (Qwen2.5-7B)Hurt
Disable query screening (ablation)ToToFilter · main benchmarksaccuracy (%): to 74.03 and 72.37Hurt

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy