Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Add INQ-7bit quantization to suggestive annotation and network training | Suggestive annotation pipeline with five FCNs · MICCAI Gland Part A | F1 score: 0.921 -> 0.930 | Improved |
| Add INQ-7bit quantization to suggestive annotation and network training | Suggestive annotation pipeline with five FCNs · MICCAI Gland Part A | Object Dice: 0.904 -> 0.914 | Improved |
| Add INQ-7bit quantization to suggestive annotation and network training | Suggestive annotation pipeline with five FCNs · MICCAI Gland Part B | F1 score: 0.855 -> 0.862 | Improved |
| Add INQ-7bit quantization to suggestive annotation and network training | Suggestive annotation pipeline with five FCNs · MICCAI Gland Part B | Object Dice: 0.858 -> 0.859 | Improved |
| Add INQ-7bit quantization to suggestive annotation and network training | Suggestive annotation pipeline with five FCNs · MICCAI Gland Part A | Object Hausdorff: 44.736 -> 41.783 | Improved |
| Add INQ-7bit quantization to suggestive annotation and network training | Suggestive annotation pipeline with five FCNs · MICCAI Gland Part B | Object Hausdorff: 96.976 -> 97.390 | Hurt |
| Use INQ-7bit instead of floating-point or INQ-5bit quantization (ablation) | Suggestive annotation FCNs · MICCAI Gland | accuracy | Improved |
| Quantize network training rather than train with floating-point representation (ablation) | Segmentation FCNs · MICCAI Gland | accuracy | Hurt |
| Use INQ with 3 bits, DoReFa-Net, or TWN instead of floating point (ablation) | Segmentation FCNs · MICCAI Gland validation | accuracy | Hurt |
| Vary the number of parallel suggestive FCNs (ablation) | Suggestive annotation · MICCAI Gland | accuracy | Mixed |
| Add quantization to suggestive annotation (ablation) | Suggestive annotation FCNs · MICCAI Gland | uncertainty | Improved |
Closest papers by meaning
- Biomedical Image Segmentation via Representative Annotation (AAAI 2019 · similarity 0.89)
- nnWNet: Rethinking the Use of Transformers in Biomedical Image Segmentation and Calling for a Unified Evaluation Benchmark (CVPR 2025 · similarity 0.88)
- Combining Fully Convolutional and Recurrent Neural Networks for 3D Biomedical Image Segmentation (NeurIPS 2016 · similarity 0.88)
- Deep Interactive Segmentation of Medical Images: A Systematic Review and Taxonomy (TPAMI 2024 · similarity 0.87)
- Generative Medical Segmentation (AAAI 2025 · similarity 0.87)
- Difficulty-Aware Attention Network with Confidence Learning for Medical Image Segmentation (AAAI 2019 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.