Research map / 3D vision / Depth and stereo
Structured Light With a Million Light Planes Per Second
Dhawal Sirikonda, Praneeth Chakravarthula, Ioannis Gkioulekas, Adithya Pediredla
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| raise scan rate from 10 to 1000 fps (ablation) | AO structured light · cat figurine | chamfer distance (mm): 1.48 -> 4.56 | Hurt |
| raise scan rate from 10 to 1000 fps (ablation) | AO structured light · cat figurine | F1: 0.830 -> 0.253 | Hurt |
| raise scan rate from 10 to 1000 fps (ablation) | AO structured light · dolphin figurine | chamfer distance (mm): 0.750 -> 2.342 | Hurt |
| raise scan rate from 10 to 100 fps (ablation) | AO structured light · cat figurine | chamfer distance (mm): 1.48 -> 1.25 | Improved |
| add accumulation of multiple scans at 1000 fps (ablation) | AO structured light · cat figurine | F1: 0.253 -> 0.641 | Improved |
| add accumulation of multiple scans at 1000 fps (ablation) | AO structured light · dolphin figurine | F1: 0.758 -> 0.955 | Improved |
| add accumulation of multiple scans at 1000 fps (ablation) | AO structured light · dolphin figurine | chamfer distance (mm): 2.342 -> 1.338 | Improved |
| add accumulation of multiple scans at 1000 fps (ablation) | AO structured light · cat figurine | recall: 0.981 -> 0.827 | Hurt |
| use AO device instead of Galvo mirror for adaptive two-line scanning at high scan rate | adaptive scanning · two orange knobs | depth error | Improved |
| scan fan at 500 fps instead of 200 fps (ablation) | AO structured light · fan at 1800 rpm | motion blur | Improved |
Closest papers by meaning
- Computational 3D Imaging with Position Sensors (ICCV 2023 · similarity 0.86)
- Event Fields: Capturing Light Fields at High Speed, Resolution, and Dynamic Range (CVPR 2025 · similarity 0.85)
- Hardware Design and Accurate Simulation of Structured-Light Scanning for Benchmarking of 3D Reconstruction Algorithms (NeurIPS 2021 · similarity 0.85)
- Single-Photon Structured Light (CVPR 2022 · similarity 0.84)
- Opportunistic Single-Photon Time of Flight (CVPR 2025 · similarity 0.83)
- Time-Efficient Light-Field Acquisition Using Coded Aperture and Events (CVPR 2024 · similarity 0.82)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.