Measured effects reported in the paper

What was changedWhereMeasuredEffect
add robust pipeline (MAD+MV+OR) on top of local normal estimatorsFS-NRSfM / FR-NRSfM · Cylinder syntheticbreakdown correspondence error rate: break at about 20% -> beyond 50%Improved
use FR-NRSfM (resultants) instead of FS-NRSfM (substitution) as baserobust pipeline · Cylinder syntheticshape and depth error: RR-NRSfM performs slightly better than RS-NRSfMImproved
increase image subset size from 5 to 7 with missing data (ablation)robust pipeline · Cylinder synthetic with missing data up to 50%reconstruction accuracy: 2.5s -> 3sImproved
increase image subset size from 7 to 10 (ablation)robust pipeline · Cylinder syntheticaccuracy vs time: 3s -> 5sNo clear effect
add OR step without MAD (ablation)FS/FR-NRSfM on error-free real data · Paper, manual-Tshirt, manual-Hulk3D points removed: almost 1% removed without MAD; 0.1% with MADMixed
add MAD before OR (ablation)OR on ASIFT datasets · Rug, ASIFT-Tshirt, ASIFT-Hulk3D points removed: almost 15% -> fewer than 0.1%Improved
add multi-view reconstruction (MVS/MVR) (ablation)FS-NRSfM / FR-NRSfM · ASIFT-Tshirt and ASIFT-Hulkreconstruction errorImproved
add MAD and MV to base estimator on error-free data (ablation)FS-NRSfM / FR-NRSfM · Paper, manual-Tshirt, manual-Hulkreconstruction errorNo clear effect
add OR step (ablation)FS-NRSfM / FR-NRSfM · error-free real datareconstruction errorImproved
replace MAD with a prior outlier-rejection method (ablation)robust pipeline · ASIFT-Tshirt / ASIFT-Hulkmean depth error (mm): 8.3 mm and 7.5 mm to 6.7 mm and 6.2 mmImproved
use MAD instead of prior outlier rejectionrobust pipeline · mismatch detection timetime per image: around 500 ms -> 150-200 msImproved
use FS/FR-NRSfM instead of Pa17normal estimation · local normal solvetime: 1.5 s -> 7-10 msImproved