AI Paper Atlas

Research map / 3D vision / Human pose estimation

iDeLog: Iterative Dual Spatial and Kinematic Extraction of Sigma-Lognormal Parameters

Miguel A. Ferrer, Moises Díaz, Cristina Carmona-Duarte, Réjean Plamondon

TPAMI 2018 · 3D vision › Human pose estimation · approach: Physics and sensor-based motion capture · 46 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use iDeLog instead of ScriptStudiotrajectory fitting · BiosecureID (preprocessed)trajectory SNR_t (dB): 6.47dB -> 23.28dBImproved
use iDeLog instead of ScriptStudiovelocity fitting · BiosecureID (preprocessed)velocity SNR_v (dB): 16.35dB -> 15.22dBHurt
use iDeLog instead of ScriptStudiotrajectory fitting · SUSIG Visual (preprocessed)trajectory SNR_t (dB): 16.39dB -> 24.11dBImproved
use iDeLog instead of ScriptStudiovelocity fitting · SUSIG Visual (preprocessed)velocity SNR_v (dB): 17.78dB -> 15.19dBHurt
add signal preprocessing (ablation)iDeLog (arcs, lognormal) · SUSIG Visualtrajectory SNR_t (dB): 21.63dB -> 24.11dBImproved
add signal preprocessing (ablation)iDeLog (arcs, lognormal) · SUSIG Visualvelocity SNR_v (dB): 10.25dB -> 15.19dBImproved
add signal preprocessing (ablation)iDeLog (arcs, lognormal) · BiosecureIDtrajectory SNR_t (dB): 22.63dB -> 23.28dBNo clear effect
link target points with clothoids instead of arcs (ablation)iDeLog (lognormal) · BiosecureID (preprocessed)trajectory SNR_t (dB): 23.28dB -> 26.62dBImproved
link target points with clothoids instead of arcs (ablation)iDeLog (lognormal) · MCYT100 (preprocessed)trajectory SNR_t (dB): 21.33dB -> 24.65dBImproved
link target points with clothoids instead of arcs (ablation)iDeLog (lognormal) · SUSIG Visual (preprocessed)trajectory SNR_t (dB): 24.11dB -> 28.43dBImproved
link target points with clothoids instead of arcs (ablation)iDeLog (lognormal) · SUSIG Visual (no preprocessing)velocity SNR_v (dB): 10.25dB -> 10.04dBHurt
use double bounded lognormal velocity bell instead of lognormal (ablation)iDeLog (clothoids) · BiosecureID (no preprocessing)velocity SNR_v (dB): 16.69dB -> 18.77dBImproved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy