Research map / 3D vision / Depth and stereo
A Generic Multi-Projection-Center Model and Calibration Method for Light Field Cameras
Qi Zhang, Chunping Zhang, Jinbo Ling, Qing Wang, Jingyi Yu A
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add distortion rectification (k1-k4) to the nonlinear optimization (ablation) | MPC model calibration · Illum-1 | RMS ray re-projection error (mm): 0.5654 -> 0.1404 | Improved |
| add distortion rectification (k1-k4) to the nonlinear optimization (ablation) | MPC model calibration · Illum-2 | RMS ray re-projection error (mm): 0.4139 -> 0.0936 | Improved |
| add distortion rectification (k1-k4) to the nonlinear optimization (ablation) | MPC model calibration · Lytro-1 | RMS ray re-projection error (mm): 0.1703 -> 0.1400 | Improved |
| add distortion rectification (k1-k4) to the nonlinear optimization (ablation) | MPC model calibration · Lytro-2 | RMS ray re-projection error (mm): 0.1316 -> 0.1124 | Improved |
| use the proposed closed-form linear initialization instead of DPW initialization | light field calibration · Illum-1 | initial RMS ray re-projection error (mm): 0.9355 -> 0.7104 | Improved |
| use the proposed closed-form linear initialization instead of DPW initialization | light field calibration · Lytro-1 | initial RMS ray re-projection error (mm): 0.6201 -> 0.3538 | Improved |
| use the proposed linear initialization on Dansereau dataset A with all 10 poses (bad corner extraction in poses 7-10) | MPC calibration · Dansereau dataset A | initial RMS ray re-projection error (mm): 0.5190 -> 15.3753 | Hurt |
| use only the 6 light fields with exactly extracted corners from dataset A (ablation) | MPC calibration · Dansereau dataset A | initial RMS ray re-projection error (mm): 15.3753 -> 0.5400 | Improved |
| calibrate with fewer poses (6 light fields) instead of all poses (ablation) | MPC calibration · Dansereau dataset D | mean re-projection error (pixel): 0.1475 -> 0.1458 | Improved |
| calibrate with fewer poses (5 light fields) instead of all poses (ablation) | MPC calibration · Dansereau dataset E | mean re-projection error (pixel): 0.2731 -> 0.2049 | Improved |
| calibrate with fewer poses (5 light fields) instead of all poses (ablation) | MPC calibration · Dansereau dataset E | RMS ray re-projection error (mm): 0.5390 -> 0.2888 | Improved |
| increase the number of poses and views in simulation (ablation) | MPC calibration · simulated data (noise 0.5 pixels) | relative error of intrinsics: less than 0.5% | Improved |
Closest papers by meaning
- Ray-Space Projection Model for Light Field Camera (CVPR 2019 · similarity 0.92)
- Principals and Pupils of Lenslet-Based Light Field Camera Calibration (TPAMI 2026 · similarity 0.91)
- Geometric Calibration of Micro-Lens-Based Light Field Cameras Using Line Features (TPAMI 2016 · similarity 0.89)
- A Unifying Model for Camera Calibration (TPAMI 2016 · similarity 0.87)
- Ray-Space Epipolar Geometry for Light Field Cameras (TPAMI 2020 · similarity 0.87)
- Semi-Calibrated Near Field Photometric Stereo (CVPR 2017 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
