A Generic Multi-Projection-Center Model and Calibration Method for Light Field Cameras

Qi Zhang, Chunping Zhang, Jinbo Ling, Qing Wang, Jingyi Yu A

TPAMI 2018 · 3D vision › Depth and stereo · approach: Non-line-of-sight imaging · 51 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add distortion rectification (k1-k4) to the nonlinear optimization (ablation)MPC model calibration · Illum-1RMS ray re-projection error (mm): 0.5654 -> 0.1404Improved
add distortion rectification (k1-k4) to the nonlinear optimization (ablation)MPC model calibration · Illum-2RMS ray re-projection error (mm): 0.4139 -> 0.0936Improved
add distortion rectification (k1-k4) to the nonlinear optimization (ablation)MPC model calibration · Lytro-1RMS ray re-projection error (mm): 0.1703 -> 0.1400Improved
add distortion rectification (k1-k4) to the nonlinear optimization (ablation)MPC model calibration · Lytro-2RMS ray re-projection error (mm): 0.1316 -> 0.1124Improved
use the proposed closed-form linear initialization instead of DPW initializationlight field calibration · Illum-1initial RMS ray re-projection error (mm): 0.9355 -> 0.7104Improved
use the proposed closed-form linear initialization instead of DPW initializationlight field calibration · Lytro-1initial RMS ray re-projection error (mm): 0.6201 -> 0.3538Improved
use the proposed linear initialization on Dansereau dataset A with all 10 poses (bad corner extraction in poses 7-10)MPC calibration · Dansereau dataset Ainitial RMS ray re-projection error (mm): 0.5190 -> 15.3753Hurt
use only the 6 light fields with exactly extracted corners from dataset A (ablation)MPC calibration · Dansereau dataset Ainitial RMS ray re-projection error (mm): 15.3753 -> 0.5400Improved
calibrate with fewer poses (6 light fields) instead of all poses (ablation)MPC calibration · Dansereau dataset Dmean re-projection error (pixel): 0.1475 -> 0.1458Improved
calibrate with fewer poses (5 light fields) instead of all poses (ablation)MPC calibration · Dansereau dataset Emean re-projection error (pixel): 0.2731 -> 0.2049Improved
calibrate with fewer poses (5 light fields) instead of all poses (ablation)MPC calibration · Dansereau dataset ERMS ray re-projection error (mm): 0.5390 -> 0.2888Improved
increase the number of poses and views in simulation (ablation)MPC calibration · simulated data (noise 0.5 pixels)relative error of intrinsics: less than 0.5%Improved