AI Paper Atlas

Research map / Detection and segmentation / Open-set and few-shot detection

Generalized Semantic Contrastive Learning via Embedding Side Information for Few-Shot Object Detection

Ruoyu Chen, Hua Zhang, Jingzhi Li, Li Liu, Zhen Huang, Xiaochun Cao

TPAMI 2025 · Detection and segmentation › Open-set and few-shot detection · approach: Few-shot object detection · 18 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add visual-attribute knowledge matrix (ablation)Ours (no aug.) · PASCAL VOC splits 1-3, all shotsAP50: 0.6-2.6 (an average of 1.4) improvementImproved
add prototype clustering after knowledge matrix (ablation)Ours · PASCAL VOC splits 1-3AP50: an average of 0.5Improved
add counterfactual data augmentation (ablation)Ours · PASCAL VOC splits 1-3AP50: average performance improvement of 0.8Improved
add knowledge matrix to FSCE (ablation)FSCE · PASCAL VOC split 1 10-shotAP50: 63.4 -> 62.5Hurt
add knowledge matrix to FSCE (ablation)FSCE · PASCAL VOC split 2 10-shotAP50: 48.7 -> 51.1Improved
add prototype clustering to FSCE (ablation)FSCE · PASCAL VOC split 1 10-shotAP50: 63.4 -> 62.1Hurt
use self-constructed knowledge matrix instead of visual-attribute matrix (ablation)Ours · PASCAL VOC split 1 10-shotAP50: 64.8 -> 60.2Hurt
use visual attributes instead of text embeddings for knowledge matrix (ablation)Ours · PASCAL VOC split 1AP50: 0.6 and 0.3 better performance on 1-shot and 10-shotImproved
use three cluster centers instead of one (ablation)Ours with visual matrix · PASCAL VOC split 1 10-shotAP50: 64.84 -> 64.21Hurt
add prototype clustering with one center (ablation)Ours with visual matrix · PASCAL VOC split 1 10-shotAP50: 64.42 -> 64.84Improved
increase contrastive temperature from 0.2 to 1 (ablation)Ours · PASCAL VOC split 1 10-shotAP50: 65.2 -> 63.2Hurt
vary lambda3 from 1 to 0.5, 1.5, 2 (ablation)Ours · PASCAL VOC split 1 10-shotAP50: 65.2 vs 64.6, 64.5, 64.7No clear effect

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy