AI Paper Atlas

Research map / 3D vision / Human pose estimation

SMPLest-X: Ultimate Scaling for Expressive Human Pose and Shape Estimation

Wanqi Yin, Zhongang Cai, Ruisi Wang, Ailing Zeng, Wei Chen, Qingping Sun, Haiyi Mei, Yanjun Wang, Hui En Pang, Mingyuan Zhang, Lei Zhang, Chen Change Loy and 3 more

TPAMI 2025 · 3D vision › Human pose estimation · approach: Heatmap and coordinate pose encoding · 45 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
scale training data from 5 to 40 datasets (ablation)SMPLer-X-L · Whole-body MPE (5 benchmarks)MPE: 97.0 -> 63.7Improved
scale training data from 5 to 40 datasets (ablation)SMPLest-X-H · Whole-body MPE (5 benchmarks)MPE: 87.5 -> 58.9Improved
increase instances from 7.5M to 10M within same 40 datasets (ablation)SMPLest-X-H · Whole-body MPE (5 benchmarks)MPE: 58.9 -> 59.9No clear effect
scale backbone from ViT-S to ViT-H (ablation)SMPLer-X-40+ · Whole-body MPE (5 benchmarks)MPE: 77.3 -> 59.9Improved
scale backbone from ViT-L to ViT-H (ablation)SMPLer-X-40 · Whole-body MPE (5 benchmarks)MPE: 63.7 -> 61.9Improved
replace component guiding module with transformer decoder and extra task tokens (SMPLest-X)SMPLer-X-H40+ · Hand MPE (6 benchmarks)hand-MPE: 35.6 -> 31.6Improved
replace component guiding module with transformer decoder and extra task tokens (SMPLest-X)SMPLer-X-H40+ · Hand PA-MPE (6 benchmarks)hand-PA-MPE: 11.1 -> 9.3Improved
select top-ranked datasets instead of bottom-ranked, 5 datasets (ablation)SMPLer-X-B · Whole-body MPE (5 benchmarks)MPE: 115.61 -> 103.47Improved
select top-ranked datasets instead of bottom-ranked, 10 datasets (ablation)SMPLer-X-B · Whole-body MPE (5 benchmarks)MPE: 115.10 -> 89.20Improved
weighted sampling instead of balanced sampling (ablation)SMPLer-X-H32 · Whole-body MPE (5 benchmarks)MPE: 63.08 -> 62.12No clear effect
concatenated sampling instead of balanced sampling (ablation)SMPLer-X-H32 · Whole-body MPE (5 benchmarks)MPE: 63.08 -> 63.32No clear effect
scale training data to 4.5M instances with CNN backbone (balanced) (ablation)Hand4Whole · Whole-body MPE (5 benchmarks)MPE: 116.59 -> 98.33Improved

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 2 of 2 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy