AI Paper Atlas

Research map / Detection and segmentation / CNN features

Learning From Partially Labeled Data for Multi-Organ and Tumor Segmentation

Yutong Xie, Jianpeng Zhang, Yong Xia, Chunhua Shen

TPAMI 2023 · Detection and segmentation › CNN features · approach: Context modeling for semantic segmentation · 48 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use Transformer instead of convolution as kernel generator (ablation)DoDNet · MOTS validation (ablation, 500 epochs)mDice: 70.98 -> 72.30Improved
use multi-scale deformable attention with 3 levels instead of single scale (ablation)TransDoDNet · MOTS validation (ablation, 500 epochs)mDice: 72.80 -> 73.79Improved
feed both CNN and Transformer features to the decoder (Mode-A) rather than CNN only (ablation)TransDoDNet · MOTS validation (ablation, 500 epochs)mDice: 72.48 -> 73.79Improved
feed both CNN and Transformer features to the decoder (Mode-A) rather than Transformer only (ablation)TransDoDNet · MOTS validation (ablation, 500 epochs)mDice: 72.60 -> 73.79Improved
increase Transformer encoder/decoder layers from 1/1 to 3/3 (ablation)TransDoDNet · MOTS validation (ablation, 500 epochs)mDice: 72.30 -> 73.37Improved
increase Transformer layers from 3/3 to 6/6 (ablation)TransDoDNet · MOTS validation (ablation, 500 epochs)mDice: 73.37 -> 73.07No clear effect
increase Transformer width from 192 to 768 (ablation)TransDoDNet · MOTS validation (ablation, 500 epochs)mDice: 73.79 -> 72.02Hurt
increase Transformer width from 96 to 192 (ablation)TransDoDNet · MOTS validation (ablation, 500 epochs)mDice: 71.55 -> 73.79Improved
increase dynamic head depth from 3 to 4 (ablation)TransDoDNet · MOTS validation (ablation, 500 epochs)mDice: 72.30 -> 71.43Hurt
increase dynamic head width from 4 to 8 (ablation)TransDoDNet · MOTS validation (ablation, 500 epochs)mDice: 71.51 -> 72.30Improved
increase dynamic head width from 8 to 16 (ablation)TransDoDNet · MOTS validation (ablation, 500 epochs)mDice: 72.30 -> 71.97Hurt
replace DoDNet with TransDoDNetDoDNet · MOTS testmDice: 76.94 -> 78.26Improved

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy