Measured effects reported in the paper

What was changedWhereMeasuredEffect
use cross-reference weights instead of equal weights in EMD (ablation)DeepEMD-FCN · miniImageNet 1-shot 5-wayaccuracy: 56.95 -> 61.13Improved
use EMD instead of dense connections with cross-reference weights (ablation)DeepEMD-FCN · miniImageNet 1-shot 5-wayaccuracy: 55.41 -> 61.13Improved
set EMD weights by K-means clustering instead of equal weights (K=10) (ablation)DeepEMD-FCN · miniImageNet 1-shot 5-wayaccuracy: 56.95 -> 56.25Hurt
set EMD weights by Mean-shift with auto bandwidth (ablation)DeepEMD-FCN · miniImageNet 1-shot 5-wayaccuracy: 56.95 -> 53.56Hurt
replace global-vector metric with EMD on local featuresDeepEMD-FCN · miniImageNet 1-shot 5-wayaccuracy: 63.08 -> 65.91Improved
add feature pyramid P_feat(5,2,1) (ablation)DeepEMD-FCN · miniImageNet 1-shot 5-wayaccuracy: 65.91 -> 66.50Improved
add image pyramid P_grid(5,3,2) (ablation)DeepEMD-Grid · miniImageNet 1-shot 5-wayaccuracy: 67.31 -> 67.83Improved
use a finer 6x6 grid instead of 3x3 (ablation)DeepEMD-Grid · miniImageNet 1-shot 5-wayaccuracy: 67.31 -> 63.61Hurt
sample more patches (9 to 25) (ablation)DeepEMD-Sampling · miniImageNet 1-shot 5-wayaccuracy: 68.09 -> 68.77Improved
add self-supervised rotation prediction in pre-training (ablation)DeepEMD-Sampling · miniImageNet 1-shot 5-wayaccuracy: 68.77 -> 69.17Improved
apply random rotation as data augmentation only (ablation)DeepEMD-Sampling · miniImageNet 1-shot 5-wayaccuracy: 68.77 -> 67.98Hurt
use OpenCV simplex solver instead of QPTH interior point at inferenceDeepEMD-FCN · EMD layer time 5x5 features 256 dimtime: 8.595 s -> 0.018 sImproved