AI Paper Atlas

Research map / Probabilistic and scientific modeling / Uncertainty and Gaussian processes

Sketching in High-Dimensional Regression With Big Data Using Gaussian Scale Mixture Priors

Rajarshi Guhaniyogi, Aaron Wolfe Scheffler

JMLR 2025 · Probabilistic and scientific modeling › Uncertainty and Gaussian processes · approach: Nonparametric and PAC-Bayes Bayesian learning

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
increase sketch size m from 100 to 500 (ablation)CHS · Simulation 1 (Scenario 1, s=50)avg accuracy (zero coefficients): 0.64 -> 0.95Improved
increase sketch size m from 100 to 500 (ablation)CHS · Simulation 1 (Scenario 1, s=50)avg accuracy (nonzero coefficients): 0.61 -> 0.86Improved
increase sketch size m from 100 to 500 at high sparsity (ablation)CHS · Simulation 1 (Scenario 1, s=10)avg accuracy (zero coefficients): 0.88 -> 0.98Improved
increase sketch size m from 100 to 500 (ablation)CHS · Simulation 1 (Scenario 1, s=10)computational efficiency: 2.83 -> 0.85Hurt
increase number of nonzero coefficients s from 10 to 50 (m=100) (ablation)CHS · Simulation 1 (Scenario 1)avg accuracy (zero coefficients): 0.88 -> 0.64Hurt
use correlated (compound) instead of independent features (ablation)CHS · Simulation 1avg accuracyNo clear effect
sketch with Gaussian random projection instead of subsampling m points (PMCP)CHS vs PMCP · Simulation 2 (Scenario 1, m=400, s=50)MSPE x10^3: 33.19 -> 0.61Improved
increase m from 200 to 400 (ablation)CHS · Simulation 2 (Scenario 1, s=50)MSPE x10^3: 205.67 -> 0.61Improved
increase m from 200 to 400 (ablation)CHS · Simulation 2 (Scenario 1, s=50)coverage of nonzero coefficients: 0.68 -> 0.97Improved
use full-data MCP instead of sketched CHSCHS · Simulation 2 (Scenario 1, m=400, s=10)MSPE x10^3: 0.51 -> 0.02Improved
increase m from 300 to 800 (ablation)CHS · Orthopedic fractures (SOF)correlation of predicted and observed response: 0.87 (m=800) vs 0.91 for MCPImproved
decrease m from 800 to 300 (ablation)CHS · Orthopedic fractures (SOF)95% predictive interval length: 0.17 -> 0.48Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy